Insulating liquids – Test methods for the determination of interfacial tension of insulating liquids – Determination with the ring method
Introduction: Interfacial tension (IFT) of insulating liquid against water has been used for a long time as a criterion for ageing evaluation. Statistical values that are used as orientation values and for their interpretation have been published in IEC 60422 [1] 1. The interfacial tension of insulating liquids changes with time depending on the type and nature of the ageing products. This process is more pronounced with aged than with new insulating liquids. It is well known that the interfacial tension of insulating liquids depends on the interfacial concentration of the surface active amphiphilic aged products at the time of measuring (dynamic interfacial tension), see Figure 1. The adsorption procedures, and thus the attaining of a state of equilibrium, can take several minutes or even hours. With the socalled static measuring methods – e.g. the Du Noüy ring [2]– measurements are repeated on the same sample surface until no further change occurs. a) Typical development of interfacial tension values of a new inhibited mineral insulating liquid b) Typical development of interfacial tension values of a service aged mineral insulating liquid Figure 1 – Typical development of interfacial tension values of new and service aged mineral insulating liquids ____________ Numbers in square brackets refer to the Bibliography. IEC 48,5 47,5 46,5 IFT new mineral insulating liquid (mN/m) New mineral insulating liquid 100 200 300 400 500 600 700 Time (s) IEC 18,5 17,5 16,5 IFT aged mineral insulating l
Scope: This document establishes the measurement of the interfacial tension between insulating liquid and water by means of the Du Noüy ring method close to equilibrium conditions. In order to obtain a value that provides a realistic expression of the real interfacial tension, a measurement after a surface age of approximately 180 s is recorded.
Contents:
- FOREWORD
- INTRODUCTION
- Scope