Mechanical structures for electrical and electronic equipment-Aisle containment for it cabinets-Part 2: Details of air flow, air separation and air cooling requirements

$100.88 $201.76 -50%
Product Code: IEC 62966-2
Stock In Stock
Edition: 1.0
Published: 07/2020
Number of Pages: 54
File Size: 1 file, 7 Bytes

Available Options

Product Description

Mechanical structures for electrical and electronic equipment – Aisle containment for it cabinets – Part 2: Details of air flow, air separation and air cooling requirements

Introduction: Cabinets of the IEC 60297 and IEC 60917 standard series are used as enclosures of electronic and electrical equipment in many different fields of application. A wide field of application is represented by enclosures equipped with electronic information technology (IT) equipment. They are frequently set up in large numbers in server rooms and data centres. During their operation, the electronic equipment installed generates a considerable amount of heat that will be removed from the equipment by means of cooling air. Precise adjustment of the supply air temperature and a sufficient cooling air flow are indispensable prerequisites for the fail-safe operation of equipment in information technology. It is a common practice to set up cabinets in rows. The server cabinets along the rows are usually arranged in such a way that surfaces with cold supply air inlets face each other across an aisle, and surfaces with hot exhaust air outlets also face each other across an aisle. This row configuration is generally known as hot aisle/cold aisle configuration. Moreover, air is supplied and discharged exclusively via the front and rear panels of the server cabinets, which are frequently perforated doors. It is assumed that inside the IT equipment, the cooling air is moved in a horizontal direction, taking it in at the front and discharging it at the rear. This part of IEC 62966 specifies the quantification of the air separation, in particular the air leak rate that describes the content of

Scope: This part of IEC 62966, dedicated to aisle containment techniques for information technology (IT) equipment typically used in data centres, describes the quantification of its air tightness, in particular the air loss ratio that describes the content of the volumetric flow not used for cooling the IT equipment. This ratio provides an index of efficiency, being inversely proportional to efficiency (the lower this ratio, the higher the efficiency). This document provides methods to measure an aisle containment air leakage rate and defines a classification system for aisle containment leakage. This document defines: a) the measurement of the air leakage of the individual components of an aisle containment; b) a method for calculating the air leakage of an aisle containment based on its individual components; c) a method for calculating the air leakage rate of an aisle containment in relation to the utilised IT equipment; d) a classification system for aisle containment leakage.

Contents:

  • FOREWORD
  • INTRODUCTION
  • Scope