Natural esters – Guidelines for maintenance and use in electrical equipment
Introduction: Natural esters are increasingly being used in transformers and electrical equipment employed in electrical power generation, transmission, distribution and industrial applications. The use of natural esters is recommended for equipment where the liquid does not remain in continuous contact with ambient air, such as hermetically sealed units, units with closed conservators equipped with a rubber bag (bladder) or external expansion elements (external bag), units with a headspace having either a nitrogen blanket or a confined volume of air (distribution transformers). Monitoring and maintaining liquid quality are essential to ensure the reliable operation of natural ester filled electrical equipment. Codes of practice for this purpose have been established by electrical power authorities, power companies and industries in many countries. A review of current experience reveals a wide variation of procedures and criteria. It is possible, however, to compare the value and significance of standardized liquid tests and to recommend uniform criteria for the evaluation of test data. If a certain amount of liquid deterioration (by degradation or contamination) is exceeded, there is inevitably some erosion of safety margins and the question of the risk of premature failure should be considered. While the quantification of the risk can be very difficult, a first step involves the identification of potential effects of increased deterioration. The philosophy underlying this document is to
Scope: This document provides procedures and guidelines that are intended for the use and maintenance of natural ester liquid in sealed transformers and other electrical equipment. This document is applicable to natural esters, originally supplied conforming to IEC 62770 and other applicable standards (e.g. ASTM D6871 [1]1) in transformers, switchgear and electrical apparatus where liquid sampling is practical and where the normal operating conditions specified in the equipment specifications apply. At present, there is a limited amount of information available for electrical equipment other than transformers. This document is also intended to assist the power equipment operator to evaluate the condition of the natural ester and maintain it in a serviceable condition. It also provides a common basis for the preparation of more specific and complete local codes of practice. The document includes recommendations on tests and evaluation procedures and outlines methods for reconditioning and reclaiming the liquid, when necessary.
Contents:
- FOREWORD
- INTRODUCTION
- Scope