Ultrasonics - Non-focusing short pressure pulse sources including ballistic pressure pulse sources - Characteristics of fields
Introduction: In this document, pressure pulses are single pulses of ultrasonic energy of up to 25 µs duration which have only one significant positive and one negative peak carrying more than 95 % of the energy (see definitions). Focused pressure pulses (sometimes called "strongly focused") are characterized by a peak acoustic pressure in a point in the sound field distant from the source aperture. Parameters and measurement methods for focusing pressure pulse sources are described in IEC 61846. The parameters and measurement methods of any other types of pressure pulses, i.e. weakly focused and non-focused pressure pulses, are described in this document. Devices with non-focusing/weakly focusing pressure pulse sources are used for the extracorporeal treatment of soft tissue pain situations in, for example, the shoulder, the heel spur or the tennis elbow and for trigger point therapy. Further, still under research are applications in orthopaedics, pain therapy, treatment of angina pectoris, stem cell therapy of infarcted cardiac areas, treatment of erectile dysfunction, of cellulitis, and wound repair. The patients receive between 3 to 5 treatments of 10 min to 20 min duration with approximately or on average 1 000 pulses. Each pressure pulse consists of one significant compressional part and a trailing negative part and has an overall duration of less than 25 µs. In present devices, 1 to 35 pulses per second are released to the target tissue. The pulses are usually applied to the patient
Scope: This document is applicable to therapy equipment using extracorporeally induced non-focused or weakly focused pressure pulses; therapy equipment producing extracorporeally induced non-focused or weakly focused mechanical energy, where the pressure pulses are released as single events of duration up to 25 µs. This document does not apply to therapy equipment using focusing pressure pulse sources such as extracorporeal lithotripsy equipment; therapy equipment using other acoustic waveforms like physiotherapy equipment, low intensity ultrasound equipment and HIFU/HITU equipment. This document specifies measurable parameters which are used in the declaration of the acoustic output of extracorporeal equipment producing a non-focused or weakly focused pressure pulse field, methods of measurement and characterization of non-focused or weakly focused pressure pulse fields. NOTE 1 The parameters defined in this document do not – at the time of publication – allow quantitative statements to be made about clinical efficacy and possible hazard. In particular, it is not possible to make a statement about the limits for these effects. NOTE 2 Figure B.1 to Figure B.10 and Figure 2 to Figure 4 are useful to understand the geometry of the field applied in this document. This document has been developed for equipment intended for use in pressure pulse therapy, for example therapy of orthopaedic pain like shoulder pain, tennis elbow pain, heel spur pain, muscular trigger point therapy, lower back pain, etc. It is not intended to be used for extracorporeal lithotripsy equipment (as described in IEC 61846), physiotherapy equipment using other waveforms (as described in IEC 61689) and HIFU/HITU equipment (see IEC 60601-2-62 and IEC TR 62649).
Contents:
- FOREWORD
- INTRODUCTION
- Scope