IEC 63186-2021 PDF

IEC 63186-2021 PDF

Nuclear power plants-Instrumentation and control systems important to safety-Criteria for seismic trip system

$100.88 $201.76 -50%
Product Code: IEC 63186
Stock In Stock
Edition: 1.0
Published: 08/2021
Number of Pages: 46
File Size: 1 file, 1 Byte

Available Options

Product Description

Nuclear power plants – Instrumentation and control systems important to safety – Criteria for seismic trip system

Introduction: a) Technical background, main issues and organization of the standard Earthquakes pose one of the major external threats to the safe operation of nuclear power plants. Structures, systems and components important to safety of a nuclear power plant are generally designed to tolerate a postulated design basis earthquake. To mitigate the adverse effects of a strong earthquake and further enhance reactor safety, the seismic trip system has been implemented in many reactor designs. Nevertheless, a dedicated IEC standard for the design of such I&C system was missing. Lessons learned from the Fukushima accident emphasize the importance of installing an automatic seismic trip system as it provides a valuable lead time and enhances the safety margins in potential accident conditions. IEC 63186 is the first effort in this field and provides technical guidance and requirements for the design of this system. It discusses general considerations for a seismic trip system and explains the rationale for the system design. Specific requirements for the system design and equipment specification are presented. Requirements for tests used to demonstrate the functionality of the designed system are also included. b) Situation of the current standard in the structure of the IEC SC 45A standard series IEC 63186 is the third level SC 45A document tackling the issue of the seismic trip system design. It is built upon a number of first and second level SC 45A documents. For example, IEC 63186 refers t

Scope: This document specifies the minimum requirements for the design of the seismic trip system, and the components thereof, used in a nuclear power plant to mitigate seismic effects. This system is intended to shut down the reactor in operation automatically before it is significantly impacted by the vibratory ground motion incurred by strong earthquakes. This document is applicable to both the design of new built plants and the upgrading of plants in operation. It may be used for the design of other types of nuclear facilities where normal operation shall be stopped in case of strong seismic motions. NOTE In addition to the seismic trip system, other names are possible for the system covered in this document, e.g. automatic seismic trip system or earthquake scram/trip system.

Contents:

  • FOREWORD
  • INTRODUCTION
  • Scope

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
IEC 63186-2021 PDF

IEC 63186-2021 PDF

$100.88 $201.76