Wearable electronic devices and technologies-Part 402-3: Performance measurement of fitness wearables-Test methods for the determination of the accuracy of heart rate

$72.51 $145.02 -50%
Product Code: IEC 63203-402-3
Stock In Stock
Edition: 1.0
Published: 01/2024
Number of Pages: 38
File Size: 1 file, 873 Bytes

Available Options

Product Description

Wearable electronic devices and technologies – Part 402-3: Performance measurement of fitness wearables – Test methods for the determination of the accuracy of heart rate

Introduction: The intent of this document is to evaluate the accuracy of wearables that measure heart rate with a photoplethysmogram (PPG) sensor. Heart rate is a widely used physiological variable that non-invasively assesses the cardiac autonomic nervous system by measuring changes in the cardiac rhythm through time. Heart rate can be measured from an electrocardiographic signal (ECG). However, the use of physiological signals other than ECG to extract heart rate information is common. The term “pulse rate” has been used in literature to reference heart rate obtained through PPG. Researchers have been using PPG to extract as much information as possible given its widespread use in clinical and everyday activities. PPG is a simple, non-invasive, optical measurement technique used for the detection of blood volume changes in peripheral tissue. Pulse rate has been treated as a synonym to heart rate and these two terms are often used interchangeably by manufacturers in describing device features to consumers. However, it is possible that the relationship or differences between heart rate and pulse rate will not be clear based on intent. Because some countries and manufacturers can use the term pulse rate rather than heart rate, the reader is encouraged to clarify preferential term, if the term is being used as a synonym, and testing expectations. Heart rate measures the rate of contractions or heartbeats whereas pulse rate measures changes in blood pressure. For an unhealthy person, these tw

Scope: This part of IEC 63203 specifies terms, a measurement protocol, and a test to evaluate the accuracy of wearables that measure heart rate with a photoplethysmogram (PPG) sensor. While this document can be used to measure a variety of different devices claiming to report heart rate, care will be taken when testing in countries that differentiate between heart rate and pulse rate. This measurement protocol is not intended to evaluate medical devices associated with the IEC 60601 series or ISO 80601 series.

Contents:

  • FOREWORD
  • INTRODUCTION
  • Scope

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
IEC 63203-402-3-2024 PDF

IEC 63203-402-3-2024 PDF

$72.51 $145.02