Underwater acoustics – Calibration of acoustic wave vector receivers in the frequency range 5 Hz to 10 kHz
Introduction: Unlike traditional piezoelectric hydrophones which are sensitive to sound pressure, vector receivers measure sound particle motion (velocity, acceleration or displacement) or sound pressure gradient, and have strongly directional response in their working frequency range. The calibration of these vector receivers which measure sound particle motion or sound pressure gradient is considered in this document. The output voltage of a vector receiver channel to be calibrated is proportional to the sound particle motion or sound pressure gradient at the reference centre of the receiver. The directivity of the vector receiver channel is independent of acoustical frequency, and the ratio of the output voltage of the receiver channel at angle θ to the maximum output voltage on the axial direction is equal to cos [1]1. Recent developments of acoustic wave vector receivers for ocean acoustics, such as those that measure sound particle velocity, have led to a number of commercial systems being made available on the market. In addition to providing sensors which possess some useful directivity for low-frequency applications, they are increasingly used for measurement of underwater noise exposure for marine fauna that are sensitive to sound particle motion rather than sound pressure (for example, fish and invertebrates). However, calibration of such sensors poses technical challenges, and is not covered by the existing international standards such as IEC 60565 [2], [3]. Building on work be
Scope: Usually, acoustic wave vector receivers are designed and constructed based on one of two principles. One is the sound pressure difference (gradient) principle. When measuring with this sensor, the vector receiver is rigidly fixed on a mount and supported in water. The other is the co-vibrating (inertial) principle. When measuring with this sensor, the vector receiver is suspended on a mount and supported in water in a non-rigid manner, which allows the vector receiver co-vibrate in the same direction as the sound particle in the sound wave field. Many methods have been used to calibrate vector receivers, such as free-field calibration, calibration in standing wave tube and calibration in a travelling wave tube. This document specifies methods and procedures for calibration of vector receivers in the frequency range 5 Hz to 10 kHz, which are applicable to vector receivers based on the two different principles. In addition, it describes an absolute method of inertial vector receiver calibration in air using optical interferometry.
Contents:
- FOREWORD
- INTRODUCTION
- Scope