Medical electrical equipment – Part 2-71: Particular requirements for the basic safety and essential performance of functional near-infrared spectroscopy (NIRS) equipment
Introduction: The minimum safety requirements specified in this document are considered to provide for a practical degree of safety in the operation of FUNCTIONAL NIRS EQUIPMENT. The requirements are followed by specifications for the relevant tests. A "Particular guidance and rationale" text giving some explanatory notes, where appropriate, about the more important requirements is included in Annex AA. It is considered that knowledge of the reasons for these requirements will not only facilitate the proper application of the standard but will, in due course, expedite any revision necessitated by changes in clinical practice or as a result of developments in technology. However, this annex does not form part of the requirements of this document.
Scope: Replacement: This part of IEC 80601 applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of FUNCTIONAL NIRS EQUIPMENT, as defined in 201.3.205, intended to be used by itself, or as a part of an ME SYSTEM hereinafter referred to as ME EQUIPMENT. HAZARDS inherent in the intended physiological function of ME EQUIPMENT or ME SYSTEMS within the scope of this document are not covered by specific requirements in this document except in IEC 60601-1:2005, IEC 60601-1:2005/AMD1:2012 and IEC 60601-1:2005/AMD2:2020, 7.2.13 and 8.4.1. NOTE Additional information can be found in IEC 60601-1:2005, IEC 60601-1:2005/AMD1:2012 and IEC 60601-1:2005/AMD2:2020, 4.2. This document is not applicable to equipment for the measurement of oxygen saturation of the haemoglobin in the micro vessels (capillaries, arterioles and venules), i.e. tissue oximeters; frequency-domain and time-domain equipment for functional near-infrared spectroscopy; equipment for the measurement of changes in the concentration of chromophores other than oxy- and deoxy-haemoglobin; equipment for the measurement of changes in the concentration of oxy- and deoxy- haemoglobin in tissues other than the brain. This document does not specify the requirements for: cerebral tissue oximeter equipment, which are given in ISO 80601-2-85 [1]1; and pulse oximeter equipment, which are given in ISO 80601-2-61 [2]. 201.1.2 Object Replacement: The object of this document is to establish particular BASIC SAFETY and ESSENTIAL PERFORMANCE requirements for FUNCTIONAL NIRS EQUIPMENT as defined in 201.3.205. NOTE This document has been prepared to address the relevant essential principles [3] and labelling principles [4] of the International Medical Devices Regulators Forum (IMDRF) as indicated in Annex DD. ___________ 1 Numbers in square brackets refer to the Bibliography. IEC 80601-2-71:2025 © IEC 2025 – 9 – 201.1.3 Collateral standards Addition: This document refers to those applicable collateral standards that are listed in Clause 2 of IEC 60601-1:2005, IEC 60601-1:2005/AMD1:2012 and IEC 60601-1:2005/AMD2:2020 and Clause 201.2 of this document. IEC 60601-1-3 and IEC 60601-1-10 [5] do not apply. All other published collateral standar
Contents: