IEC CISPR 16-1-5-2016 PDF

IEC CISPR 16-1-5-2016 PDF

Specification for radio disturbance and immunity measuring apparatus and methods-Part 1-5: Radio disturbance and immunity measuring apparatus-Antenna calibration sites and reference test sites for 5 MHz to 18 GHz

$428.74 $857.48 -50%
Product Code: IEC CISPR 16-1-5
Stock In Stock
Edition: 2.1
Published: 12/2016
Number of Pages: 385
File Size: 0 files

Available Options

Product Description

Specification for radio disturbance and immunity measuring apparatus and methods – Part 1-5: Radio disturbance and immunity measuring apparatus – Antenna calibration sites and reference test sites for 5 MHz to 18 GHz

Introduction: This standard describes validation procedures for Calibration Test Sites (CALTS) that are used to calibrate antennas in the frequency range 5 MHz to 18 GHz. The associated antenna calibration procedures are described in CISPR 16-1-6. Due to problems with suppressing ground reflections in the frequency range 30 MHz to 200 MHz, the main function of a reflecting ground plane is for the calibration of dipole, biconical, and hybrid antennas over the frequency range for which their H-plane patterns are uniform. The free-space antenna factor, Fa, for dipole antennas may be measured in a free- space environment above 200 MHz. Because of the difficulty of reducing reflections from objects that surround an antenna, and in particular the ground surface, a flat metal ground plane is used to ensure reproducibility of results and to enable the ground reflected signal to be precisely removed mathematically. Requirements for the construction of a CALTS are given in Annex A. The specifications and validation procedures for a CALTS are given in Clause 4. The most precise way of validating a CALTS is to use calculable dipole antennas, which are the basis of the validation procedure in this standard. The design principles of calculable antennas are given in Annex B, and the theory and methods for calculating site insertion loss (SIL) are given in Annex C and Annex D. Validation procedures for other antenna calibration sites are given in Clause 5 through Clause 7. Where an antenna calibration met

Scope: This part of CISPR 16 specifies the requirements for calibration sites in the frequency range 5 MHz to 18 GHz used to perform antenna calibrations according to CISPR 16-1-6. It also specifies the requirements for reference test sites (REFTS) that are used for the validation of compliance test sites (COMTS) in the frequency range 30 MHz to 1 000 MHz according to CISPR 16-1-4. It has the status of a basic EMC standard in accordance with IEC Guide 107, Electromagnetic compatibility – Guide to the drafting of electromagnetic compatibility publications. Measurement instrumentation specifications are given in CISPR 16-1-1 [1]1 and CISPR 16-1- 4. Further information and background on uncertainties in general is given in CISPR 16-4 [3], which can also be helpful in establishing uncertainty estimates for the calibration processes of antennas and site validation measurements.

Contents:

  • FOREWORD
  • INTRODUCTION
  • Scope
  • 1 000 MHz

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
IEC CISPR 16-1-5-2016 PDF

IEC CISPR 16-1-5-2016 PDF

$428.74 $857.48