IEC/IEEE 62704-1-2026 PDF

IEC/IEEE 62704-1-2026 PDF

Determining the peak spatial-average specific absorption rate (SAR) in the human body from wireless communications devices, 100 kHz to 10 GHz - Part 1: General requirements for using the finite-difference time-domain (FDTD) method for SAR calculations

$239.59 $479.18 -50%
Product Code: IEC/IEEE 62704-1
Stock In Stock
Edition: 2.0
Published: 10/2026
Number of Pages: 88
File Size: 1 file, 2.4 MB

Available Options

Product Description

Determining the peak spatial-average specific absorption rate (SAR) in the human body from wireless communications devices, 100 kHz to 10 GHz - Part 1: General requirements for using the finite-difference time-domain (FDTD) method for SAR calculations

Introduction: Computational techniques have reached a level of maturity which allows their use in specific absorption rate (SAR) assessment of wireless communication devices. Some wireless communication devices are used in situations where SAR measurement is extremely complex or not possible at all. The benefits of consensus standards to users and regulators include standardized and accepted protocols, anatomically correct body models, verification and validation techniques, benchmark data, reporting format and means for estimating the computational uncertainty in order to produce valid, accurate, repeatable, and reproducible data.

Scope: This part of IEC/IEEE 62704 defines the methodology for the application of the finite-difference time domain (FDTD) technique when used for determining the peak spatial-average specific absorption rate (psSAR) in the human body exposed to wireless communication devices with known uncertainty. It defines methods to validate the computational model of the device under test (DUT) and to assess its uncertainty when used in SAR simulations. Moreover, it defines procedures to determine the psSAR in a cubical volume and to verify the correct implementation of the FDTD simulation software. The applicable frequency range is 100 kHz to 10 GHz. This document does not recommend specific SAR limits; these are found elsewhere, for example, in the guidelines published by the International Commission on Non-Ionizing Radiation Protection (ICNIRP) [1]1 or in IEEE Std C95.1 [2].

Contents:

  • FOREWORD
  • INTRODUCTION
  • Scope

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
IEC/IEEE 62704-1-2026 PDF

IEC/IEEE 62704-1-2026 PDF

$239.59 $479.18