IEC/IEEE TR 63572-2026 PDF

IEC/IEEE TR 63572-2026 PDF

Evaluation of absorbed power density related to human exposure to radio frequency fields from wireless communication devices operating between 6 GHz and 300 GHz

$255.36 $510.71 -50%
Product Code: IEC/IEEE TR 63572
Stock In Stock
Edition: 1.0
Published: 03/2026
Number of Pages: 114
File Size: 1 file

Available Options

Product Description

Evaluation of absorbed power density related to human exposure to radio frequency fields from wireless communication devices operating between 6 GHz and 300 GHz

Introduction: This document describes computational and measurement methods for the evaluation of absorbed (epithelial) power density related to human exposures due to electromagnetic field (EMF) transmitting devices operating in close proximity to the user at frequencies between 6 GHz and 300 GHz. The types of devices include but are not limited to mobile telephones, tablets, laptops, etc. For portable devices, the specific absorption rate (SAR) assessment standard for wireless devices used in close proximity to the user IEC/IEEE 62209-1528:2020 [1] is specified up to 10 GHz. The IEC/IEEE 63195-1 and IEC/IEEE 63195-2 standards on the assessment of the incident power density (IPD) for wireless devices used in close proximity to the user are valid from 6 GHz to 300 GHz. For exposure to EMF emitted from base stations, IEC 62232:2022 [2] specifies methods to assess the compliance boundaries based on reference levels and basic restrictions for a frequency range from 110 MHz to 300 GHz. The absorbed power density (APD) is considered as the relevant local basic restriction and exposure metric above 6 GHz in the ICNIRP 2020 guidelines [3] and in the Health Canada Notice [4]. Similarly, IEEE Std C95.1™-2019 [5] requires equivalent assessment of epithelial power density above 6 GHz. IEC PAS 63446 [6] describes methods to convert SAR results into APD in frequency range of 6 GHz to 10 GHz. IEC TC 106 and IEEE ICES TC 34 (IEC/IEEE) have previously noted the necessity to extend compliance assessment st

Scope: This document describes the computation and measurement techniques and test approaches for evaluating the local peak absorbed power density (pAPD) and peak spatial average absorbed (epithelial) power density (psAPD) induced in a human body from a wireless device transmitting in close proximity to the user at frequencies between 6 GHz and 300 GHz. This document provides information on the testing of portable devices transmitting at distances close to the human body, such as mobile phones, tablets, wearable devices, etc. The information in this document is also relevant to exposure in the close proximity of base stations.

Contents:

  • FOREWORD
  • INTRODUCTION
  • Scope

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
IEC/IEEE TR 63572-2026 PDF

IEC/IEEE TR 63572-2026 PDF

$255.36 $510.71