Rotating electrical machines-Part 27-3: Dielectric dissipation factor measurement on stator winding insulation of rotating electrical machines

$132.41 $264.81 -50%
Product Code: IEC 60034-27-3
Stock In Stock
Edition: 1.0
Published: 12/2015
Number of Pages: 59
File Size: 1 file, 856 Bytes

Available Options

Product Description

Rotating electrical machines – Part 27-3: Dielectric dissipation factor measurement on stator winding insulation of rotating electrical machines

Introduction: This International Standard provides guidelines for dielectric dissipation factor measurements on form-wound stator bars or coils as well as for complete windings. The dielectric dissipation factor is a measure of the dielectric losses in the stator winding in- sulation. Measurement of dielectric dissipation factor is an appropriate means of assessing the quality of new and also aged stator winding insulation of rotating electrical machines. Es- pecially, the method is useful for assessing the uniform quality of manufacturing and the die- lectric behaviour of the insulation as a whole. For aged stator windings, the dielectric dissipa- tion factor provides information about insulation condition. The dielectric dissipation factor measurements give no indication of the distribution of loss within the insulation and – in contrast to off-line partial discharge measurements – do not permit localization of weak points of the insulation system. The main principle is to measure the dielectric dissipation factor over a range of voltages and to derive different characteristic dielectric loss parameters as basis for the evaluation. Empirical limits verified in practice can be used as a basis for evaluating the quality of stator winding insulation systems in manufacturing. Furthermore, trend evaluation, e.g. diagnostic tests as part of the functional evaluation of insulation systems or in connection with servicing and overhaul of rotating machines, can also provide information on ageing p

Scope: This part of IEC 60034 provides guidelines for the test procedures and the interpretation of test results for dielectric dissipation factor measurements on the stator winding insulation of rotating electrical machines. These guidelines are valid for rotating electrical machines with conductive slot coatings operating at a rated voltage of 6 kV and higher. This standard applies to individual form-wound stator bars and coils outside a core (unin- stalled), individual stator bars and coils installed in a core and complete form-wound stator winding of machines in new or aged condition. This International Standard applies to all kind of vacuum impregnated or resin-rich (fully- loaded) taped bars, coils and complete windings. It is not applicable to non-impregnated indi- vidual bars and coils or non-impregnated complete windings. Requirements for the dielectric dissipation factor characteristics of individual form-wound sta- tor bars and coils of machines with rating voltages from 6 kV and higher when tested with 50 Hz or 60 Hz alternating voltages are given.

Contents:

  • FOREWORD
  • INTRODUCTION
  • Scope