IEC 60044-1-2003 PDF

IEC 60044-1-2003 PDF

Instrument transformers-Part 1: Current transformers

$324.71 $649.42 -50%
Product Code: IEC 60044-1
Stock In Stock
Edition: 1.2
Published: 02/2003
Number of Pages: 116
File Size: 1 file, 805 Bytes

Available Options

Product Description

Instrument transformers – Part 1: Current transformers

Scope: This part of IEC 60044 applies to newly manufactured current transformers for use with electrical measuring instruments and electrical protective devices at frequencies from 15 Hz to 100 Hz. Although the requirements relate basically to transformers with separate windings, they are also applicable, where appropriate, to autotransformers. Clause 11 covers the requirements and tests, in addition to those in clauses 3 to 10, that are necessary for current transformers for use with electrical measuring instruments. Clause 12 covers the requirements and tests, in addition to those in clauses 3 to 10, that are necessary for current transformers for use with electrical protective relays, and in particular for forms of protection in which the prime requirement is the maintenance of accuracy up to several times the rated current. For certain protective systems, where the current transformer characteristics are dependant on the overall design of the protective equipment (for example high-speed balanced systems and earth-fault protection in resonant earthed networks), additional requirements are given in clause 13 for class PR transformers and in clause 14 for class PX transformers. Clause 13 covers the requirements and tests in addition to those in clauses 3 to 10 that are necessary for current transformers for use with electrical protective relays, and in particular for forms of protection in which the prime requirement is the absence of remanent flux. Clause 14 covers the requirements and tests in addition to those in clauses 3 to 10 that are necessary for current transformers for use with electrical protective relays, and in particular for forms of protection for which knowledge of the transformer’s secondary excitation characteristic, secondary winding resistance, secondary burden resistance and turns ratio is sufficient to assess its performance in relation to the protective relay system with which it is to be used. Current transformers intended for both measurement and protection shall comply with all the clauses of this standard. 1.2

Contents:

  • FOREWORD
  • Scope
  • 3.1 Normal service conditions
  • 3.2 Special service conditions
  • 3.3 System earthing
  • 4.1 Standard values of rated primary currents
  • 4.2 Standard values of rated secondary currents
  • 4.3 Rated continuous thermal current
  • 4.4 Standard values of rated output
  • 4.5 Short-time current ratings
  • 4.6 Limits of temperature rise
  • 5.1 Insulation requirements
  • 5.2 Mechanical requirements
  • 6.1 Type tests
  • 6.2 Routine tests
  • 6.3 Special tests
  • 7.1 Short-time current tests
  • 7.2 Temperature-rise test
  • 7.3 Impulse tests on primary winding
  • 7.4 Wet test for outdoor type transformers
  • 7.5 Radio interference voltage measurement
  • 8.1 Verification of terminal markings
  • 8.2 Power-frequency withstand tests on primary windings and partial discharge
  • 8.3 Power-frequency withstand tests between sections of primary and secondary
  • 8.4 Inter-turn overvoltage test