IEC 60052-2002 PDF

IEC 60052-2002 PDF

Voltage measurement by means of standard air gaps

$132.41 $264.81 -50%
Product Code: IEC 60052
Stock In Stock
Edition: 3.0
Published: 10/2002
Number of Pages: 64
File Size: 1 file, 829 Bytes

Available Options

Product Description

Voltage measurement by means of standard air gaps

Introduction: Sphere-gaps have been used as a simple and reliable method for measurement of peak voltage in many industrial test facilities for 75 years, and the values of tables I and II in the second edition of IEC 60052 have been accepted as an International Consensus Standard of Measurements. These tables appear in this standard as tables 2 and 3. There is no information in the references (e.g. annex A) with regard to traceability to national standards of measurement. However, the dispersion in the measured values of sparkover voltages upon which tables 2 and 3 are based, does not exceed 3 % for a 95 % confidence level. In view of the long history of IEC 60052 as an International Consensus Standard of Measurement, the values for disruptive discharge voltage in tables I and II of the second edition of IEC 60052 are reproduced in this publication as tables 2 and 3. They are to be used as mean values with an uncertainty of 3 % for a 95 % confidence level. The material on rod-rod gaps for reliable measurement of high direct voltages has been included here to form an integrated standard on high voltage measurements using standard air gaps. Four informative annexes are included: Annex A gives the limits of voltage and frequency over which tables 2 and 3 have been derived from experiments and can be presumed to be accurate within the limits specified in 4.1. Annex B gives the procedure by which the values in tables 2 and 3 have been derived from previous national standards and other sources.

Scope: IEC 60052 sets forth recommendations concerning the construction and use of standard air gaps for the measurement of peak values of the following four types of voltage: a) alternating voltages of power frequencies; b) full lightning impulse voltages; c) switching impulse voltages; d) direct voltages. Air gaps constructed and used in accordance with this standard represent IEC standard measuring devices in accordance with IEC 60060-2 and are primarily intended for performance checks of high voltage measuring systems.

Contents:

  • FOREWORD
  • INTRODUCTION
  • Scope

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
IEC 60052-2002 PDF

IEC 60052-2002 PDF

$132.41 $264.81