Insulation co-ordination – Part 5: Procedures for high-voltage direct current (HVDC) converter stations
Introduction: The IEC 60071 series consists of the following parts under the general title Insulation co- ordination: Part 1: Definitions, principles and rules Part 2: Application guide Part 4: Computational guide to insulation co-ordination and modelling of electrical networks Part 5: Procedures for high-voltage direct current (HVDC) converter stations
Scope: This part of IEC 60071 provides guidance on the procedures for insulation co-ordination of high-voltage direct current (HVDC) converter stations, without prescribing standardized insulation levels. This standard applies only for HVDC applications in high-voltage a.c. power systems and not for industrial conversion equipment. Principles and guidance given are for insulation co- ordination purposes only. The requirements for human safety are not covered by this standard. 1.2 Additional background The use of power electronic thyristor valves in a series and/or parallel arrangement, along with the unique control and protection strategies employed in the conversion process, has ramifications requiring particular consideration of overvoltage protection of equipment in converter stations compared with substations in a.c. systems. This standard outlines the procedures for evaluating the overvoltage stresses on the converter station equipment subjected to combined d.c., a.c. power frequency, harmonic and impulse voltages. The criteria for determining the protective levels of series and/or parallel combinations of surge arresters used to ensure optimal protection are also presented. The basic principles and design objectives of insulation co-ordination of converter stations, in so far as they differ from normal a.c. system practice, are described. Concerning surge arrester protection, this standard deals only with metal-oxide surge arresters, without gaps, which are used in modern HVDC converter stations. The basic arrester characteristics, requirements for these arresters and the process of evaluating the maximum overvoltages to which they may be exposed in service, are presented. Typical arrester protection schemes and stresses of arresters are presented, along with methods to be applied for determining these stresses. This standard includes insulation co-ordination of equipment connected between the converter a.c. bus (including the a.c. harmonic filters, the converter transformer, the circuit breakers) and the d.c. line side of the smoothing reactor. The line and cable terminations in so far as they influence the insulation co-ordination of converter station equipment
Contents:
- FOREWORD
- INTRODUCTION
- Scope