IEC 60076-3-2018 PDF

IEC 60076-3-2018 PDF

Power transformers-Part 3: Insulation levels, dielectric tests and external clearances in air

$349.93 $699.85 -50%
Product Code: IEC 60076-3
Stock In Stock
Edition: 3.1
Published: 03/2018
Number of Pages: 242
File Size: 1 file, 2 Bytes

Available Options

Product Description

Power transformers – Part 3: Insulation levels, dielectric tests and external clearances in air

Introduction: This part of IEC 60076 specifies the insulation requirements and the corresponding insulation tests with reference to specific windings and their terminals. It also recommends external clearances in air (Clause 16). The insulation levels and dielectric tests which are specified in this standard apply to the internal insulation only. Whilst it is reasonable that the rated withstand voltage values which are specified for the internal insulation of the transformer should also be taken as a reference for its external insulation, this may not be true in all cases. A failure of the non-self-restoring internal insulation is catastrophic and normally leads to the transformer being out of service for a long period, while an external flashover may involve only a short interruption of service without causing lasting damage. Therefore, it may be that, for increased safety, higher test voltages are specified by the purchaser for the internal insulation of the transformer than for the external insulation of other components in the system. When such a distinction is made, the external clearances should be adjusted to fully cover the internal insulation test requirements. Annex E sets out some of the principles used in assigning the tests, test levels and clearances in air to the transformer according to the highest voltage for equipment Um.

Scope: This International Standard applies to power transformers as defined by and in the scope of IEC 60076-1. It gives details of the applicable dielectric tests and minimum dielectric test levels. Recommended minimum external clearances in air between live parts and between live parts and earth are given for use when these clearances are not specified by the purchaser. For categories of power transformers and reactors which have their own IEC standards, this standard is applicable only to the extent in which it is specifically called up by cross reference in the other standards.

Contents:

  • FOREWORD
  • INTRODUCTION
  • Scope
  • 10 Applied voltage test (AV)
  • 11 Induced voltage tests (IVW and IVPD)
  • 11.1 General
  • 11.2 Induced voltage withstand test (IVW)
  • 11.3 Induced voltage test with partial discharge measurement (IVPD)
  • 11.3.1 General
  • 11.3.2 Test duration and frequency
  • 11.3.3 Test sequence
  • 11.3.4 Partial discharge (PD) measurement
  • 11.3.5 Test acceptance criteria
  • 12 Line terminal AC withstand test (LTAC)
  • 13 Lightning impulse tests (LI, LIC, LIN, LIMT)
  • 13.1 Requirements for all lightning impulse tests
  • 13.1.1 General
  • 13.1.2 Tap positions
  • 13.1.3 Records of tests
  • 13.1.4 Test connections
  • 13.2 Full wave lightning impulse test (LI)
  • 13.2.1 Wave shape, determination of test voltage value and tolerances
  • 13.2.2 Tests on transformers without non-linear elements
  • 13.2.3 Tests on transformers with non-linear elements
  • 13.3 Chopped wave lightning impulse test (LIC)

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
IEC 60076-3-2018 PDF

IEC 60076-3-2018 PDF

$349.93 $699.85