Power transformers – Part 7: Loading guide for mineral-oil-immersed power transformers

Introduction: This part of IEC 60076 provides guidance for the specification and loading of power transformers from the point of view of operating temperatures and thermal ageing. It provides recommendations for loading above the nameplate rating and guidance for the planner to choose appropriate rated quantities and loading conditions for new installations. IEC 60076-2 is the basis for contractual agreements and it contains the requirements and tests relating to temperature-rise figures for oil-immersed transformers during continuous rated loading. It should be noted that IEC 60076-2 refers to the average winding temperature rise while this part of IEC 60076 refers mainly to the hot-spot temperature and the stated values are provided only for guidance. This part of IEC 60076 gives mathematical models for judging the consequence of different loadings, with different temperatures of the cooling medium, and with transient or cyclical variation with time. The models provide for the calculation of operating temperatures in the transformer, particularly the temperature of the hottest part of the winding. This hot-spot temperature is, in turn, used for evaluation of a relative value for the rate of thermal ageing and the percentage of life consumed in a particular time period. The modelling refers to small transformers, here called distribution transformers, and to power transformers. A major change from IEC 60354:1991 is the increased use of fibre optic temperature sensors in transformers. This

Scope: This part of IEC 60076 is applicable to mineral-oil-immersed transformers. It describes the effect of operation under various ambient temperatures and load conditions on transformer life. NOTE For furnace transformers, the manufacturer should be is consulted in view of the peculiar loading profile.

Contents:

  • FOREWORD
  • INTRODUCTION
  • Scope

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
IEC 60076-7 (REDLINE + STANDARD)-2018 PDF

IEC 60076-7 (REDLINE + STANDARD)-2018 PDF

$407.31 $814.61