Explosive atmospheres - Part 29-0: Gas detection equipment - General requirements and test methods
Introduction: This part of IEC 60079-29 specifies general requirements, test methods and acceptance criteria that apply to flammable, oxygen and toxic gas detection equipment intended to detect gases and vapours and to provide an indication, alarm or other output function for personnel or property protection in industrial and commercial applications. This part of IEC 60079-29 was developed for the purpose of aligning requirements and test methods of gas detection equipment within a single consolidated document for consistency. Although a wide range of conditions can be encountered in practice, this document specifies requirements to be fulfilled by gas detection equipment when tested under prescribed laboratory conditions. General and performance requirements for Type TX-HM gas detection equipment intended for occupational exposure measurement in the region of Occupational Exposure Limit Values are set out in IEC 62990-1. Consideration needs to also be given to the following relevant international standards: IEC 60079-29-2, Explosive atmospheres - Part 29-2: Gas detectors - Selection, installation, use and maintenance of detectors for flammable gases and oxygen IEC 62990-2, Workplace atmospheres - Part 2: Gas detectors - Selection, installation, use and maintenance of detectors for toxic gases and vapours IEC 60079-29-3, Explosive atmospheres - Part 29-3: Gas detectors - Guidance on functional safety of fixed gas detection systems
Scope: This part of IEC 60079-29 specifies general requirements, test methods and acceptance criteria that apply to flammable, oxygen and toxic gas detection equipment intended to detect gases and vapours and to provide an indication, alarm or other output function for personnel or property protection in industrial and commercial applications. NOTE 1 The term gas detection equipment is often referred to as the term gas detector. NOTE 2 The terms 'gas' and 'gases' used in this document are also intended to include 'vapour' and 'vapours'. This document applies to the following gas detection equipment: Gas detection equipment Type "FL" intended for the detection of flammable gases: Type FL-Group I, in mines susceptible to firedamp; Type FL-Group II, in locations other than mines susceptible to firedamp; and Type FL-OP, open path gas detection equipment for flammable gases. Gas detection equipment Type "O2" intended for the detection of oxygen: Type O2-DE, detection of oxygen deficiency or oxygen enrichment; and Type O2-IN, inertisation as measuring function for explosion protection. NOTE 3 Inertisation is an explosion protection technique where an explosive atmosphere is purged with inert gas. Gas detection equipment Type "TX" intended for the detection of toxic gases: Type TX-SM, detection in areas for safety monitoring applications and typically using alarm signalling; Type TX-HM, occupational exposure measurement in the region of occupational exposure limit values; and NOTE 4 Type TX-HM gas detection equipment performance requirements reside in IEC 62990-1. Type TX-OP, open path gas detection equipment for toxic gases. NOTE 5 This document addresses equipment giving a level of performance suitable for general purpose applications. Specific applications might require particular tests or evaluations that are additional to and separate from the compliance with this document. NOTE 6 Although the focus of this document is gas detection equipment for use in 'explosive atmospheres', this document can be applicable to detection in areas not formally classified as 'explosive atmospheres'. NOTE 7 Refrigerant gas detection equipment used for life, health and safety area monitorin
Contents:
- FOREWORD
- INTRODUCTION
- Scope