IEC 60079-31 (REDLINE + STANDARD)-2022 PDF

IEC 60079-31 (REDLINE + STANDARD)-2022 PDF

Explosive atmospheres-Part 31: Equipment dust ignition protection by enclosure "t"

$123.58 $247.16 -50%
Product Code: IEC 60079-31 (REDLINE + STANDARD)
Stock In Stock
Edition: 3.0
Published: 01/2022
Number of Pages: 69
File Size: 1 file

Available Options

Product Description

Explosive atmospheres – Part 31: Equipment dust ignition protection by enclosure "t"

Introduction: The International Electrotechnical Commission (IEC) draws attention to the fact that it is claimed that compliance with this document may involve the use of a patent. IEC takes no position concerning the evidence, validity, and scope of this patent right. The holder of this patent right has assured IEC that s/he is willing to negotiate licences under reasonable and non-discriminatory terms and conditions with applicants throughout the world. In this respect, the statement of the holder of this patent right is registered with IEC. Information may be obtained from the patent database available at http://patents.iec.ch. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights other than those in the patent database. IEC shall not be held responsible for identifying any or all such patent rights.

Scope: This part of IEC 60079 is applicable to electrical equipment protected by enclosure and surface temperature limitation for use in explosive dust atmospheres. It specifies requirements for design, construction and testing of electrical equipment Ex Equipment and Ex Components. This document supplements and modifies the general requirements of IEC 60079-0. Where a requirement of this document conflicts with a requirement of IEC 60079-0, the requirement of this document takes precedence. This document does not apply to dusts of explosives, which do not require atmospheric oxygen for combustion, or to pyrophoric substances. This document does not apply to electrical equipment Ex Equipment or Ex Components intended for use in underground parts of mines as well as those parts of surface installations of such mines endangered by firedamp and/or combustible dust. This document does not take account of any risk hazard due to an emission of flammable or toxic gas from the dust. Consideration of additional protective measures is required where the application of electrical equipment is in atmospheres, which can contain combustible dust and explosive gas, whether simultaneously or separately. This document does not contain requirements for Ex Equipment used in areas where both combustible dust and explosive gas atmospheres can occur, whether simultaneously or separately. Requirements for explosive gas atmospheres can be found in other parts of the IEC 60079 series. Guidance on Ex Equipment to be used where combustible dust and explosive gas atmospheres occur simultaneously ("hybrid mixtures") can be found in IEC 60079-14. Where the electrical equipment Ex Equipment has to meet other environmental conditions, for example, protection against ingress of water and resistance to corrosion, additional measures which do not adversely affect the integrity of the enclosure can be necessary. The measures used should not adversely affect the integrity of the enclosure.

Contents:

  • FOREWORD
  • INTRODUCTION
  • Scope

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
IEC 60079-31 (REDLINE + STANDARD)-2022 PDF

IEC 60079-31 (REDLINE + STANDARD)-2022 PDF

$123.58 $247.16