Surge arresters-Part 8: Metal-oxide surge arresters with external series gap (EGLA) for overhead transmission and distribution lines of a.c. systems above 1 kV

$239.59 $479.18 -50%
Product Code: IEC 60099-8
Stock In Stock
Edition: 2.0
Published: 11/2017
Number of Pages: 72
File Size: 1 file

Available Options

Product Description

Surge arresters – Part 8: Metal-oxide surge arresters with external series gap (EGLA) for overhead transmission and distribution lines of a.c. systems above 1 kV

Introduction: This part of IEC 60099 applies to the externally gapped line arrester (EGLA) This type of surge arrester is connected directly in parallel with an insulator assembly. It comprises a series varistor unit (SVU), made up from non-linear metal-oxide resistors encapsulated in a polymer or porcelain housing, and an external series gap (see Figure 1). The purpose of an EGLA is to protect the parallel-connected insulator assembly from lightning-caused over-voltages. The external series gap, therefore, should spark over only due to fast-front over-voltages. The gap should withstand all power-frequency and slow-front over-voltages occurring on the system. In the event of SVU failure, the external series gap should be able to isolate the SVU from the system. Figure 1 – Configuration of an EGLA with insulator and arcing horn IEC Insulator assembly (insulator assembly, with/without arcing horns or grading elements) External series gap (without an insulator in parallel) Series varistor unit Conductor Tower arm EGLA

Scope: This part of IEC 60099 covers metal-oxide surge arresters with external series gap (externally gapped line arresters (EGLA)) that are applied on overhead transmission and distribution lines, only to protect insulator assemblies from lightning-caused flashovers. This document defines surge arresters to protect the insulator assembly from lightning-caused over-voltages only. Therefore, and since metal-oxide resistors are not permanently connected to the line, the following items are not considered for this document: switching impulse spark-over voltage; residual voltage at steep current and switching current impulse; thermal stability; long-duration current impulse withstand duty; power-frequency voltage versus time characteristics of an arrester; disconnector test; aging duties by power-frequency voltage. Considering the particular design concept and the special application on overhead transmission and distribution lines, some unique requirements and tests are introduced, such as the verification test for coordination between insulator withstand and EGLA protective level, the follow current interrupting test, mechanical load tests, etc. Designs with the EGLA's external series gap installed in parallel to an insulator are not covered by this document.

Contents:

  • FOREWORD
  • INTRODUCTION
  • Scope

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
IEC 60099-8-2017 PDF

IEC 60099-8-2017 PDF

$239.59 $479.18