IEC 60118-9-2019 PDF

IEC 60118-9-2019 PDF

Electroacoustics-Hearing aids-Part 9: Methods of measurement of the performance characteristics of bone conduction hearing aids

$132.41 $264.81 -50%
Product Code: IEC 60118-9
Stock In Stock
Edition: 2.0
Published: 09/2019
Number of Pages: 58
File Size: 1 file, 1 Byte

Available Options

Product Description

Electroacoustics – Hearing aids – Part 9: Methods of measurement of the performance characteristics of bone conduction hearing aids

Introduction: IEC 60118-0 gives information on methods of measurement for air conduction hearing aids. The majority of hearing aids in use are of this type, but a small percentage use a bone vibrator instead of an earphone. The use of a bone vibrator requires a different method of measuring the output from the hearing aid and also makes it impractical to measure amplification directly in terms of acoustic gain. Amplification in the case of an air conduction hearing aid is expressed as the difference between the output sound pressure level in an acoustic coupler or ear simulator and the input sound pressure level measured in a specified manner. However, with bone conduction hearing aids, the input is in terms of sound pressure level, but the output will be in terms of mechanical vibration measured as a vibratory force or force level. By means of information provided in this document, the performance of hearing aids with bone vibrator outputs which do not form an integral part of the hearing aid, for example body- worn, behind-the-ear hearing aids, or bone conduction implant systems with an external bone vibrator, can be measured in a similar manner to aids with air conduction outputs as described in IEC 601180. Where the bone vibrator forms an integral part of the hearing aid, or where it is attached in some fixed manner to the hearing aid, for example a bone coupled (bone anchored) hearing aid, its performance cannot be measured in the same way as for body-worn aids, due to the large dimen

Scope: This part of IEC 60118 specifies methods for the measurement of bone conduction hearing aid characteristics. The methods described will produce a suitable basis for the exchange of information or for direct comparison of the electroacoustical characteristics of bone conduction hearing aids. These methods are chosen to be practical and reproducible and are based on selected fixed parameters. The results obtained by the methods specified in this document express the performance under the conditions of measurement; however, the performance of the hearing aid under practical conditions of use will depend upon a number of factors (e.g. effective load impedance, environmental conditions, acoustical environment, etc.). This document defines methods of measurement of characteristics of bone conduction hearing aids both for transcutaneously coupled devices measured on a mechanical coupler, meeting the requirements of IEC 60318-6, and bone coupled/bone anchored devices measured on a skull simulator. NOTE 1 A skull simulator is a mechanical coupler designed to present a specific mechanical impedance to mechanically coupled vibrator. NOTE 2 Throughout this document, all sound pressure levels specified are referred to 20 µPa. When appropriate, sound pressure level will be abbreviated to SPL.

Contents:

  • FOREWORD
  • INTRODUCTION
  • Scope

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
IEC 60118-9-2019 PDF

IEC 60118-9-2019 PDF

$132.41 $264.81