Measuring relays and protection equipment – Part 27: Product safety requirements (Commented Version)
Introduction: In order to demonstrate that the equipment is safe, it was previously necessary to refer to general safety standards such as IEC 61010-1 in addition to IEC 60664-1. These general safety standards specify requirements for general product types or product families in order to reduce the risk of fire, electric shock or injury to the user. The product types do not include measuring relays and protection equipment. These standards also take into account single-fault conditions. Reference to all these various standards created confusion due to conflicting requirements, for example, different clearances, creepage distances and test voltages etc., for the same rated voltages. The aim of this standard is: to remove confusion due to conflicting requirements between existing standards; to achieve a uniform approach throughout the international industry for measuring relays and protection equipment. This product safety standard for measuring relays and protection equipment takes the general product safety standards and IEC 60664-1 as the base, defining those issues specific to measuring relays and protection equipment. This document specifies the safety requirements that are generally applicable to all equipment within its scope. These requirements may be supplemented by general product safety standards and IEC 60664-1.
Scope: This part of IEC 60255 describes specifies the product safety requirements for measuring relays and protection equipment having a rated AC voltage up to 1 000 V with a rated frequency up to 65 Hz, or a rated DC voltage up to 1 500 V. Above these limits, IEC 60664-1 is applicable for the determination of clearance, creepage distance and withstand test voltage. This document details specifies essential safety requirements to minimize the risk of fire and hazards caused by electric shock or injury to the user and property. This document specifies only product safety requirements; functional performance of the equipment is not covered. 1 This standard does not cover the safety requirements of installations. This document covers all the ways in which the equipment may can be mounted and used in cubicles cabinets, racks and panels, and also retesting. This document also applies to auxiliary devices such as shunts, series resistors, transformers, auxiliary control panels, display devices, etc., that are used in conjunction with measuring relays and protection equipment and are tested together. It is possible that ancillary equipment such as network switches used in conjunction with measuring relays and protection equipment may need needs to comply with additional safety requirements. This standard is intended to describe only product safety requirements; therefore, functional performance of the equipment is not covered. Functional safety requirements, including EMC functional safety, are not covered by this standard. Functional safety risk analysis is not within the scope of this product safety standard. This document does not specify the implementation of individual equipment, circuits and components. The object of this standard is to have a comprehensive standard that covers all aspects of product safety and the related type and routine tests, for measuring relays and protection equipment. This document applies to equipment designed to be safe at least under the following environmental conditions: indoor use; altitude up to 2 000 m, in accordance with IEC 60255-1; external operating temperature range, in accordance with IEC 60255-1; rated ambient temperature range, i
Contents:
- FOREWORD
- INTRODUCTION
- Scope