Electric cables - Calculation of the current rating - Part 2: Thermal resistance - Section 1: Calculation of thermal resistance
Introduction: The IEC 60287 series has been divided into three parts so that revisions of, and additions to the document can be carried out more conveniently. Each part is subdivided into subparts which are published as separate standards. Part 1: Formulae of ratings and power losses; Part 2: Formulae for thermal resistance; Part 3: Operating conditions. This part of IEC 60287-2 contains methods for calculating the internal thermal resistance of cables and the external thermal resistance for cables laid in free air, ducts and buried. The formulae in this document contain quantities which vary with cable design and materials used. The values given in the tables are either internationally agreed, for example, electrical resistivities and resistance temperature coefficients, or are those which are generally accepted in practice, for example, thermal resistivities and permittivities of materials. In this latter category, some of the values given are not characteristic of the quality of new cables but are considered to apply to cables after a long period of use. In order that uniform and comparable results can be obtained, the current ratings should be calculated with the values given in this document. However, where it is known with certainty that other values are more appropriate to the materials and design, then these may be used, and the corresponding current rating declared in addition, provided that the different values are quoted. Quantities related to the operating conditions of cables
Scope: This part of IEC 60287 is solely applicable to the conditions of steady-state operation of cables at all alternating voltages, and direct voltages up to 5 kV, buried directly in the ground, in ducts, in troughs or in steel pipes, both with and without partial drying-out of the soil, as well as cables in air. The term "steady state" is intended to mean a continuous constant current (100 % load factor) just sufficient to produce asymptotically the maximum conductor temperature, the surrounding ambient conditions being assumed constant. This document provides formulae for thermal resistance. The formulae given are essentially literal and designedly leave open the selection of certain important parameters. These can be divided into three groups: parameters related to construction of a cable (for example, thermal resistivity of insulating material) for which representative values have been selected based on published work; parameters related to the surrounding conditions which can vary widely, the selection of which depends on the country in which the cables are used or will be used; parameters which result from an agreement between manufacturer and user and which involve a margin for security of service (for example, maximum conductor temperature). Equations given in this document for calculating the external thermal resistance of a cable buried directly in the ground or in a buried duct are for a limited number of installation conditions. Where analytical methods are not available for calculation of external thermal resistance finite element methods can be used. Guidance on the use of finite element methods for calculating cable current ratings is given in IEC TR 62095.
Contents:
- FOREWORD
- INTRODUCTION
- Scope