Low-voltage electrical installations – Part 7-701: Requirements for special installations or locations – Locations containing a bath or shower
Introduction: For the purpose of this part of IEC 60364 (IEC 60364-7-701) the requirements of the general Parts 1 to 6 and Parts 8 of IEC 60364 apply. The IEC 60364-7-7XX parts of IEC 60364 contain particular requirements for special installations or locations which are based on the requirements of the general parts of IEC 60364 (IEC 60364-1 to IEC 60364-6 and IEC 60364-8). These IEC 60364-7-7XX parts are considered in conjunction with the requirements of the general parts. The particular requirements of this part of IEC 60364 supplement, modify or replace certain of the requirements of the general parts of IEC 60364 being valid at the time of publication of this part. The absence of reference to the exclusion of a part or a clause of a general part means that the corresponding clauses of the general part are applicable (undated reference). Requirements of other 7XX parts being relevant for installations covered by this part also apply. This part may therefore also supplement, modify or replace certain of these requirements valid at the time of publication of this part. The clause numbering of this part follows the pattern and corresponding references of IEC 60364. The numbers following the particular number of this part are those of the corresponding parts, or clauses of the other parts of the IEC 60364 series, valid at the time of publication of this part, as indicated in the normative references of this document (dated reference). If requirements or explanations additional to those of t
Scope: The particular requirements of this part of IEC 60364 apply to electrical installations in indoor or outdoor locations where a bath tub and/or a shower is intended to be permanently placed in a specific location. The extent of the location containing a bath tub and/or a shower is limited by: the lowest finished floor level; a horizontal plane 3 m above the lowest finished floor level; a vertical circumscribing virtual surface at a distance of 4 m from the fixed water outlet for the bath tub or shower; and the volume within the walls, floor and ceiling that border the location containing a bath or shower, measured to a depth of 6 cm. NOTE 1 Where the shower head and flexible hose are detachable, the fixed water outlet is taken to be at the supply end of the flexible hose. The requirements of this document also apply to fixed electrical installations in mobile applications, for example caravans, mobile homes, shower containers. This document does not apply to emergency facilities, for example emergency showers used in industrial areas or laboratories. NOTE 2 For locations containing a bath or shower for medical treatment, special requirements can be necessary. NOTE 3 For prefabricated bath and/or shower units, see also IEC 60335-2-105. 701.2
Contents:
- FOREWORD
- INTRODUCTION
- 701 Locations containing a bath or shower
- Scope