IEC 60426-2007 PDF

IEC 60426-2007 PDF

Electrical insulating materials-Determination of electrolytic corrosion caused by insulating materials-Test methods

$132.41 $264.81 -50%
Product Code: IEC 60426
Stock In Stock
Edition: 2.0
Published: 01/2007
Number of Pages: 58
File Size: 1 file, 1 Byte

Available Options

Product Description

Electrical insulating materials – Determination of electrolytic corrosion caused by insulating materials – Test methods

Introduction: Electrical insulating materials at high atmospheric humidity and under influence of electric stress may cause corrosion of metal parts being in contact with them. Such electrolytic corrosion is dependent upon the composition of the insulating material and the character of the metal; it is influenced by temperature, relative humidity, nature of the voltage and the time of exposure. Direct voltage produces much more rapid and extensive corrosion than alterna- ting voltage. Corrosion is more pronounced at the positive electrode. Not only copper but also most other metals, except the noble metals such as platinum or gold, are subject to electrolytic corrosion. Electrolytic corrosion, however, is usually determined with insulating materials in contact with copper, brass or aluminium. Copper, however, is a basic metal and most frequently used in electrotechnical, teletechnical and electronic equipment, especially for current conducting parts and therefore it was chosen as a basic test metal. Other metals may be used when needed for special purposes, but the results may differ from those described in this method. Electrolytic corrosion may cause open-circuit failure in electrical conductors and devices. It may promote low resistance leakage path across or through electrical insulation and the products of corrosion may otherwise interfere with the operation of electrical devices, i.e. may prevent operation of contacts, etc. Electronic equipment operating under conditions of high humi

Scope: This standard determines the ability of insulating materials to produce electrolytic corrosion on metals being in contact with them under the influence of electric stress, high humidity and elevated temperature. The effect of electrolytic corrosion is assessed in one test by using consecutively two methods: visual semi-quantitative method consisting in comparing visually the corrosion appearing on the anode and cathode metal strips, with those given in the reference figures. This method consists of the direct visual assessment of the degree of corrosion of two copper strips, acting as anode and cathode respectively, placed in contact with the tested insulating material under a d.c. potential difference at specified environmental conditions. The degree of corrosion is assessed by visually comparing the corrosion marks on the anode and cathode metal strips with those shown in the reference figures; quantitative method, which involves the tensile strength measurement, carried out on the same anode and cathode metal strips after visual inspection. An additional quantitative test method for determining electrolytic corrosion, which involves tensile strength measurement of copper wire, is described in the informative Annex C.

Contents:

  • FOREWORD
  • INTRODUCTION
  • Scope
  • 10 Evaluation
  • 10.1 General evaluation
  • 10.2 Visual inspection of the test strips
  • 10.3 Tensile strength of test strips
  • 11 Evaluation of corrosion on copper strips
  • 12 Test report

Be the first to write a review for this product.