Measurement of quartz crystal unit parameters – Part 6: Measurement of drive level dependence (DLD)
Introduction: The drive level (expressed as power/voltage across or current through the crystal unit) forces the resonator to produce mechanical oscillations by way of piezoelectric effect. In this process, the acceleration work is converted to kinetic and elastic energy and the power loss to heat. The latter conversion is due to the inner and outer friction of the quartz resonator. The frictional losses depend on the velocity of the vibrating masses and increase when the oscillation is no longer linear or when critical velocities, elongations or strains, excursions or accelerations are attained in the quartz resonator or at its surfaces and mounting points (see Annex A). This causes changes in resistance and frequency, as well as further changes due to the temperature dependence of these parameters. At “high” drive levels (e.g. above 1 mW or 1 mA for AT-cut crystal units) changes are observed by all crystal units and these also can result in irreversible amplitude and frequency changes. Any further increase of the drive level may could destroy the resonator. Apart from this effect, changes in frequency and resistance are observed at “low” drive levels in some crystal units (e.g. below 1 mW μW or 50 μA for AT-cut crystal units). In this case, if the loop gain is not sufficient, the start-up of the oscillation is difficult. In crystal filters, the transducer attenuation and ripple will change. Furthermore, the coupling between a specified mode of vibration and other modes (e.g. of the reson
Scope: This part of IEC 60444 applies to the measurements of drive level dependence (DLD) of quartz crystal units. Two test methods (A and C) and one referential method (B) are described. “Method A”, based on the π-network according to IEC 60444-1 IEC 60444-5, can be used in the complete frequency range covered by this part of IEC 60444. “Reference Method B”, based on the π- network or reflection method according to IEC 60444-1, IEC 60444-5 or IEC 60444-8 can be used in the complete frequency range covered by this part of IEC 60444. “Method C”, an oscillator method, is suitable for measurements of fundamental mode crystal units in larger quantities with fixed conditions. NOTE The measurement methods specified in this document are not only applicable to AT-cut, but also to other crystal cuts and vibration modes, such as doubly rotated cuts (IT,SC) and to tuning fork crystal units (by using a high impedance test fixture).
Contents:
- FOREWORD
- INTRODUCTION
- Scope