IEC 60444-7-2004 PDF

IEC 60444-7-2004 PDF

Measurement of quartz crystal unit parameters . Part 7: Measurement of activity and frequency dips of quartz crystal units

$15.77 $31.53 -50%
Product Code: IEC 60444-7
Stock In Stock
Edition: 1.0
Published: 04/2004
Number of Pages: 14
File Size: 1 file, 215 Bytes

Available Options

Product Description

Measurement of quartz crystal unit parameters . Part 7: Measurement of activity and frequency dips of quartz crystal units

Introduction: The tolerable activity dips of resonant resistance and frequency (Bandbreak) will be specified in the detail specification. The measurement and evaluation of the activity/frequency dip for the quartz crystal unit requires special consideration as it uses the linear least squares method.

Scope: This standard applies to activity and frequency dips for quartz crystal units over a temperature range. Definitions 2.1 activity dip undesirable change in the crystal unit’s load resonance frequency and/or resonance resistance caused by the coupling of different modes in a narrow temperature range and at a specified load capacitance and level of drive (see Figures 1 and 2) 2.2 frequency dip (bandbreak) undesirable perturbation or fluctuation in the crystal frequency occurring in a narrow temperature range as a deviation of the load resonance frequency from the smooth regular frequency temperature characteristic described by a polynomial of up to the 5th order. It usually shows an associated resistance change (see Figure 2) and the effect is usually drive level dependent Measurements The following measurement parameters are necessary and should be given in the detail specification: operating temperature range; load capacitance; level of drive. The evaluation of the data is made using a computer and is described in 3.3. Care shall be taken in selecting a suitable measurement time; this will depend on the type of crystal unit being measured. The drive current (in microamperes) shall also be correct and controlled. The inspection method is selected from the following and specified in the individual specification: a) lot inspection and guaranteed by process control; b) sample inspection. 3.1 Reference method The measurement system consists of a π-network in accordance with IEC 60444 and a high precision temperature chamber, which allows to ramp-up the temperature at a constant small rate.

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
IEC 60444-7-2004 PDF

IEC 60444-7-2004 PDF

$15.77 $31.53