Medical electrical equipment – Diagnostic X-rays – Part 1: Determination of quality equivalent filtration and permanent filtration
Introduction: The review of the second edition of IEC 60522 published in 1999 pointed to a number of technical issues. The analysis of these issues is laid down in the accompanying Technical Report, IEC TR 60522-2 [2]. This Technical Report identifies those items which are substantially modified in the first edition of IEC 60522-1 compared with the second edition of IEC 60522, and elucidates the analyses which led to the many new rationales and new approaches for the determination of the QUALITY EQUIVALENT FILTRATION. While the second edition of IEC 60522 covers only PERMANENT FILTRATION, IEC 60522-1 also covers quite generally “material filtering the X-RAY BEAM incident on the PATIENT”. This concerns materials like ADDED FILTERS, a PATIENT table, a breast COMPRESSION DEVICE, and materials in the BEAM LIMITING DEVICE. For these materials the defined term FILTERING MATERIAL has been introduced. With the extension by FILTERING MATERIAL, IEC 60522-1 now explicitly covers what IEC 60601- 1-3:2008 requires in its Subclause 7.4 for irremovable materials, i.e. .
Scope: This document applies to X-RAY TUBE ASSEMBLIES and to FILTERING MATERIAL, in medical diagnostic applications up to a HIGH VOLTAGE of 150 kV. For HIGH VOLTAGES greater than 50 kV, this document applies to X-RAY TUBE ASSEMBLIES with tungsten or tungsten-alloy TARGETS only. NOTE 1 The FILTERING MATERIAL in the X-RAY BEAM can be removable or irremovable; it can be positioned in any orientation or can have any shape (e.g. tapering thickness) – although usually plane-parallel material, perpendicular to the REFERENCE AXIS is applied. Examples of FILTERING MATERIALS are ADDED FILTERS, a PATIENT table (in case of an under-table X-RAY TUBE ASSEMBLY), materials in the BEAM LIMITING DEVICE, or a breast COMPRESSION DEVICE. NOTE 2 The methodology and statement of compliance given in this document is for flat FILTERS only, but the methodology can be used for any kind of non-flat FILTER. In that case further data are included in order to produce useful results, e.g. field size, geometry/position of FILTER, etc. This document defines the concept of PERMANENT FILTRATION of X-RAY TUBE ASSEMBLIES, and it defines the term FILTERING MATERIAL. Methods are given to determine the PERMANENT FILTRATION of an X-RAY TUBE ASSEMBLY and for determining the QUALITY EQUIVALENT FILTRATION of FILTERING MATERIALS. It contains requirements for statements of compliance of X-RAY TUBE ASSEMBLIES in ACCOMPANYING DOCUMENTS and for markings on X-RAY TUBE ASSEMBLIES, and for indications and statements of compliance of FILTERING MATERIAL. NOTE 3 This document does not contain requirements for any specific values of PERMANENT FILTRATION. For X-RAY EQUIPMENT used for diagnostic purposes, FILTRATION requirements are given in e.g. IEC 60601-1-3:2008 and IEC 60601-1-3:2008/AMD1:2013 or in the applicable particular standard. NOTE 4 The method of determination described in this document is suitable as a type test. It is not intended as a test to be applied by the USER.
Contents:
- FOREWORD
- INTRODUCTION
- Scope