Industrial-Process Control Valves - Part 8: Noise Considerations - Section 3: Control Valve Aerodynamic Noise Prediction Method
Introduction: The mechanical stream power as well as acoustical efficiency factors are calculated for various flow regimes. These acoustical efficiency factors give the proportion of the mechanical stream power which is converted into internal sound power. This method also provides for the calculation of the internal sound pressure and the peak frequency for this sound pressure, which is of special importance in the calculation of the pipe transmission loss. At present, a common requirement by valve users is the knowledge of the sound pressure level outside the pipe, typically 1 m downstream of the valve or expander and 1 m from the pipe wall. This standard offers a method to establish this value. The equations in this standard make use of the valve sizing factors as used in IEC 60534-1 and IEC 60534-2-1. In the usual control valve, little noise travels through the wall of the valve. The noise of interest is only that which travels downstream of the valve and inside of the pipe and then escapes through the wall of the pipe to be measured typically at 1 m downstream of the valve body and 1 m away from the outer pipe wall. Secondary noise sources may be created where the gas exits the valve outlet at higher Mach numbers. This method allows for the estimation of these additional sound levels which can then be added logarithmically to the sound levels created within the valve. Although this prediction method cannot guarantee actual results in the field, it yields calculated predictions within
Scope: This part of IEC 60534 establishes a theoretical method to predict the external sound- pressure level generated in a control valve and within adjacent pipe expanders by the flow of compressible fluids. This method considers only single-phase dry gases and vapours and is based on the perfect gas laws. This standard addresses only the noise generated by aerodynamic processes in valves and in the connected piping. It does not consider any noise generated by reflections from external surfaces or internally by pipe fittings, mechanical vibrations, unstable flow patterns and other unpredictable behaviour. It is assumed that the downstream piping is straight for a length of at least 2 m from the point where the noise measurement is made. This method is valid only for steel and steel alloy pipes (see Equations (21) and (23) in 5.5). The method is applicable to the following single-stage valves: globe (straight pattern and angle pattern), butterfly, rotary plug (eccentric, spherical), ball, and valves with cage trims. Specifically excluded are the full bore ball valves where the product FpC exceeds 50 % of the rated flow coefficient. For limitations on special low noise trims not covered by this standard, see Clause 8. When the Mach number in the valve outlet exceeds 0,3 for standard trim or 0,2 for low noise trim, the procedure in Clause 7 is used The Mach number limits in this standard are as follows: Mach number location Mach number limit Clause 5 Standard trim Clause 6 Noise-reducing trim Clause 7 High Mach number applications Freely expanded jet Mj No limit No limit No limit Valve outlet Mo 0,3 0,2 1,0 Downstream reducer inlet Mr Not applicable Not applicable 1,0 Downstream pipe M2 0,3 0,2 0,8
Contents:
- FOREWORD
- INTRODUCTION
- Scope