Medical electrical equipment – Dose area product meters

Introduction: Diagnostic radiology is the largest contributor to man-made ionizing radiation to which the public is exposed. The reduction in the exposure received by PATIENTS undergoing MEDICAL RADIOLOGICAL EXAMINATIONS or procedures has therefore become a central issue in recent years. The purpose of routine measurement of DOSE AREA PRODUCT is to help in achieving an overall reduction in the radiation received by PATIENTS undergoing MEDICAL RADIOLOGICAL EXAMINATIONS. Provided adequate records are kept, it is possible to determine PATIENT doses, to compare different examination techniques, to establish a technique giving minimum RADIATION to a PATIENT, and to ensure a maintenance of that technique; in this respect, such measurements have a place of particular importance in training establishments. Examination of records may also indicate a deterioration in the efficiency of the image-production system.

Scope: This document specifies the performance and testing of DOSE AREA PRODUCT METERS intended to measure DOSE AREA PRODUCT and/or DOSE AREA PRODUCT RATE to which the PATIENT is exposed during MEDICAL RADIOLOGICAL EXAMINATIONS. This document is applicable to the following types of DOSE AREA PRODUCT METERS: a) FIELD-CLASS DOSE AREA PRODUCT METERS normally used for the measurement of DOSE AREA PRODUCTS during MEDICAL RADIOLOGICAL EXAMINATIONS; b) REFERENCE-CLASS DOSE AREA PRODUCT METERS normally used for the CALIBRATION of FIELD- CLASS DOSIMETERS. NOTE REFERENCE-CLASS DOSE AREA PRODUCT METERS can be used as FIELD-CLASS DOSE AREA PRODUCT METERS. The object of this document is 1) to establish requirements for a satisfactory level of performance for DOSE AREA PRODUCT METERS, and 2) to standardize the methods for the determination of compliance with this level of performance. Two levels of performance are specified: a lower level of performance applying to FIELD-CLASS DOSE AREA PRODUCT METERS; a higher level of performance applying to REFERENCE-CLASS DOSE AREA PRODUCT METERS.

Contents:

  • FOREWORD
  • INTRODUCTION
  • Scope

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
IEC 60580-2019 PDF

IEC 60580-2019 PDF

$163.93 $327.86