IEC 60599 CMV-2022 PDF

IEC 60599 CMV-2022 PDF

Mineral oil-filled electrical equipment in service-Guidance on the interpretation of dissolved and free gases analysis (Commented Version)

$327.86 $655.72 -50%
Product Code: IEC 60599 CMV
Stock In Stock
Edition: 4.0
Published: 05/2022
Number of Pages: 126
File Size: 1 file

Available Options

Product Description

Mineral oil-filled electrical equipment in service – Guidance on the interpretation of dissolved and free gases analysis (Commented Version)

Introduction: Dissolved and free gas analysis (DGA) is one of the most widely used diagnostic tools for detecting and evaluating faults in electrical equipment filled with insulating liquid. However, interpretation of DGA results is often complex and should always be done with care, involving experienced insulation maintenance personnel. This document gives information for facilitating this interpretation. The first edition, published in 1978, has served the industry well, but had its limitations, such as the absence of a diagnosis in some cases, the absence of concentration levels and the fact that it was based mainly on experience gained from power transformers. The second edition (2015) attempted to address some of these shortcomings. Interpretation schemes were based on observations made after inspection of a large number of faulty oil-filled equipment in service and concentrations levels deduced from analyses collected worldwide.

Scope: This document describes how the concentrations of dissolved gases or free gases may can be interpreted to diagnose the condition of oil-filled electrical equipment in service and suggest future action. This document is applicable to electrical equipment filled with mineral insulating oil and insulated with cellulosic paper or pressboard-based solid insulation. Information about specific types of equipment such as transformers (power, instrument, industrial, railways, distribution), reactors, bushings, switchgear and oil-filled cables is given only as an indication in the application notes (see Annex A). This document may can be applied, but only with caution, to other liquid-solid insulating systems. In any case, the indications obtained should be viewed are given only as guidance and any with resulting action should be undertaken only with proper engineering judgment.

Contents:

  • FOREWORD
  • INTRODUCTION
  • Scope

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
IEC 60599 CMV-2022 PDF

IEC 60599 CMV-2022 PDF

$327.86 $655.72