Medical electrical equipment – Part 2-1: Particular requirements for the basic safety and essential performance of electron accelerators in the range 1 MeV to 50 MeV
Introduction: The use of ELECTRON ACCELERATORS for RADIOTHERAPY purposes may expose PATIENTS to danger if the ME EQUIPMENT fails to deliver the required dose distribution to the PATIENT, or if the ME EQUIPMENT design fails to meet the requirements of BASIC SAFETY and ESSENTIAL PERFORMANCE. The ME EQUIPMENT may also cause danger to persons in the vicinity if the ME EQUIPMENT itself fails to contain the RADIATION adequately or if there are inadequacies in the design of the TREATMENT ROOM. This particular standard establishes requirements to be complied with by MANUFACTURERS in the design and construction of ELECTRON ACCELERATORS for use in RADIOTHERAPY; it does not attempt to define their optimum performance requirements. Its purpose is to identify those features of design that are regarded, at the present time, as essential for the safe operation of such ME EQUIPMENT. It places limits on the degradation of ME EQUIPMENT performance beyond which it can be presumed that a fault condition exists and where an INTERLOCK then operates to prevent continued operation of the ME EQUIPMENT. Clauses 201.10, 201.103, 201.104, 201.105 and 201.108 contain limits beyond which INTERLOCKS prevent, INTERRUPT or TERMINATE IRRADIATION in order to insure ESSENTIAL PERFORMANCE is maintained to avoid an unsafe condition. In this document, the information in Clause 201.10 has either been reorganized or moved to other clauses in order to better reflect current usage and broaden the applicability of certain clauses to
Scope: Replacement: This part of IEC 60601 applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of ELECTRON ACCELERATORS, hereafter referred to as ME EQUIPMENT, in the range 1 MeV to 50 MeV, used for TREATMENT of PATIENTS. NOTE 1 While ELECTRON ACCELERATORS used for TREATMENT of PATIENTS are always ME EQUIPMENT, there are times in this document where they are referred to as EXTERNAL BEAM EQUIPMENT (EBE). Usage of EBE does not remove the requirements placed on the ME EQUIPMENT but is meant to clarify that the ME EQUIPMENT being discussed is the EBE and not some other ME EQUIPMENT that may be part of the system configuration. This particular standard, with the inclusion of TYPE TESTS and SITE TESTS, applies to the manufacture and some installation aspects of ELECTRON ACCELERATORS and their included equipment used to increase the precision, accuracy and volumetric targeting of the TREATMENT delivery intended for RADIOTHERAPY in medical practice, including those in which the selection and DISPLAY of TREATMENT PARAMETERS can be controlled automatically by PROGRAMMABLE ELECTRONIC SUBSYSTEMS (PESS), that, under NORMAL CONDITIONS and in NORMAL USE, deliver a RADIATION BEAM of X-RADIATION or ELECTRON RADIATION having NOMINAL ENERGY in the range 1 MeV to 50 MeV, maximum ABSORBED DOSE RATES between 0,001 Gy × s–1 and 1 Gy × s–1 at the ERP from the RADIATION SOURCE, and REFERENCE TREATMENT DISTANCES (RTDs) between 0,5 m and 2 m from the RADIATION SOURCE; and intended to be for NORMAL USE, operated under the authority of the RESPONSIBLE ORGANIZATION by QUALIFIED PERSONS appropriately licensed or having the required skills for a particular medical application, for particular SPECIFIED clinical purposes, maintained in accordance with the recommendations given in the INSTRUCTIONS FOR USE, and subject to regular QUALITY ASSURANCE performance and calibration checks by a QUALIFIED PERSON. ___________ The general standard is IEC 60601-1:2005 and IEC 60601-1:2005/AMD1:2012, Medical electrical equipment – Part 1: General requirements for basic safety and essential performance. – 10 – IEC 60601-2-1:2020 © IEC 2020 NOTE 2 In this particular standard, all references to installation refer to i
Contents:
- FOREWORD
- INTRODUCTION
- Scope
- 201.10 Protection against unwanted and excessive RADIATION HAZARDS
- 201.10.101 ME EQUIPMENT intended to produce therapeutic X-RADIATION and
- 201.11 Protection against excessive temperatures and other HAZARDS
- 201.12 Accuracy of controls and instruments and protection against hazardous
- 201.13 HAZARDOUS SITUATIONS and fault conditions for ME EQUIPMENT
- 201.14 PROGRAMMABLE ELECTRICAL MEDICAL SYSTEMS (PEMS)
- 201.14.101 PROGRAMMABLE ELECTRONIC SUBSYSTEMS (PESS)
- 201.15 Construction of ME EQUIPMENT
- 201.16 ME SYSTEMS
- 201.17 ELECTROMAGNETIC COMPATIBILITY of ME EQUIPMENT and ME SYSTEMS
- 201.17.101 Additional requirements
- 201.17.102 Radio-frequency EMISSIONS
- 201.17.103 IMMUNITY to radio-frequency electromagnetic fields
- 201.101 * ELECTRONIC IMAGING DEVICES (e.g. EPID)
- 201.102 Date and time format
- 201.103 EXTERNAL MONITORING DEVICES
- 201.103.1 Selection, VERIFICATION, and DISPLAY of EXTERNAL MONITORING DEVICES
- 201.103.2 BEAM GATING