Medical electrical equipment - Part 2-17: Particular requirements for the basic safety and essential performance of automatically-controlled brachytherapy afterloading equipment
Introduction: The delivery of RADIOTHERAPY over short distances is called BRACHYTHERAPY. BRACHYTHERAPY is delivered by positioning RADIATION SOURCES within or adjacent to the tissue to be treated. Historically, RADIOACTIVE SOURCES were handled manually, resulting in IRRADIATION of the OPERATOR’S hands. AFTERLOADING generally refers to the technique of placing an applicator into or adjacent to the tissue to be treated, and introducing one or more RADIATION SOURCE(S) only after the applicator position has been confirmed. This procedure minimizes the time during which the operator is exposed to the RADIATION SOURCE(S). Manual AFTERLOADING techniques were developed in the 1950s and are used routinely today for permanent implants, but less frequently for temporary implants. Temporary implants require the use of higher dose rates, to ensure that the treatment can be completed in a length of time easily tolerated by the PATIENT. In the 1980s, automatic remote AFTERLOADING techniques were developed, that could move a RADIOACTIVE SOURCE or SOURCES through connecting tubes from a shielded safe to the applicators implanted in the patient. Because the SOURCE(S) could be moved remotely, the risk of exposure to personnel could be eliminated. In 2007 an automatic remote afterloader was introduced that replaced the conventional RADIOACTIVE SOURCE(S) with an X-ray source. This device otherwise performed similarly to AFTERLOADERS containing RADIOACTIVE SOURCES. However, the X-ray source could be disabled wh
Scope: 201.1. Replacement: This International Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of automatically-controlled BRACHYTHERAPY AFTERLOADING ME EQUIPMENT, hereafter referred to as ME EQUIPMENT. If a clause or subclause is specifically intended to be applicable to ME EQUIPMENT only, or to ME SYSTEMS only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to ME EQUIPMENT and to ME SYSTEMS, as relevant. HAZARDS inherent in the intended physiological function of ME EQUIPMENT or ME SYSTEMS within the scope of this standard are not covered by specific requirements in this standard except in 7.2.13 and 8.4.1 of the general standard. NOTE See also 4.2 of the general standard. This standard applies to automatically-controlled BRACHYTHERAPY AFTERLOADING ME EQUIPMENT used for treatment or alleviation of disease. This standard specifies requirements a) for automatically-controlled AFTERLOADING ME EQUIPMENT 1) which contains and uses only beta, gamma, or NEUTRON-emitting SEALED RADIOACTIVE SOURCES, or BRACHYTHERAPY X-RAY SOURCES designed and constructed for use with automatically-controlled AFTERLOADING ME EQUIPMENT, 2) which automatically drives the RADIATION SOURCE(S) from a STORAGE CONTAINER or, in the case of BRACHYTHERAPY X-RAY SOURCES, a reference location outside the PATIENT, to a treatment position inside the SOURCE APPLICATOR(S) and returns the RADIATION SOURCE(S) to the STORAGE CONTAINER or the BRACHYTHERAPY X-RAY SOURCE(S) to the reference location, 3) which is designed for connection to a PATIENT, and 4) with which movements of the RADIATION SOURCE(S) are carried out automatically by the ME EQUIPMENT according to a prescribed programme using a powered mechanism whose changes are controlled by the CONTROLLING TIMER(S) and TIMING DEVICES that are either PROGRAMMABLE ELECTRONIC SUB-SYSTEMS (PESS) (computer or microprocessors) or non-programmable systems and b) for ME EQUIPMENT intended to be ————————— The general standard is IEC 60601-1:2005+A1:2012, Medical electrical equipment – Part 1: General requirements for basic safety and essential performance – 8 – 60601-2-17 IEC:20
Contents: