Medical electrical equipment – Part 2-24: Particular requirements for the basic safety and essential performance of infusion pumps and controllers
Introduction: This particular standard deals with the safety of INFUSION PUMPS and INFUSION CONTROLLERS. The relationship between this particular standard, IEC 60601-1:2005+A1:2012, and the collateral standards is explained in 1.3. The safe use of INFUSION PUMPS and controllers is primarily the responsibility of the OPERATOR. It is also recognized that OPERATORS should be trained in the operation of MEDICAL ELECTRICAL EQUIPMENT and that safe use of the MEDICAL ELECTRICAL EQUIPMENT can only be achieved if it is operated in accordance with the MANUFACTURER’S instructions for use. The minimum specified safety requirements are considered to provide a practical degree of safety in operation. It is the responsibility of the MANUFACTURER to ensure that the requirements of this particular standard are reliably implemented. This particular standard has been developed in accordance with these principles.
Scope: Replacement: This Particular Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of INFUSION PUMPS and VOLUMETRIC INFUSION CONTROLLERS, hereafter referred to as ME EQUIPMENT. This standard applies to ADMINISTRATION SETS insofar as their characteristics influence the BASIC SAFETY or ESSENTIAL PERFORMANCE of INFUSION PUMPS and VOLUMETRIC INFUSION CONTROLLERS. However this standard does not specify requirements or tests for other aspects of ADMINISTRATION SETS If a clause or subclause is specifically intended to be applicable to ME EQUIPMENT only, or to ME SYSTEMS only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to ME EQUIPMENT and to ME SYSTEMS, as relevant. HAZARDS inherent in the intended physiological function of ME EQUIPMENT or ME SYSTEMS within the scope of this standard are not covered by specific requirements in this standard except in 7.2.13 and 8.4.1 of the general standard. NOTE See also 4.2 of the general standard. This particular standard specifies the requirements for ENTERAL NUTRITION PUMPS, INFUSION PUMPS, INFUSION PUMPS FOR AMBULATORY USE, SYRINGE OR CONTAINER PUMPS, VOLUMETRIC INFUSION CONTROLLERS and VOLUMETRIC INFUSION PUMPS, as defined in 201.3.204, 201.3.206, 201.3.207, 201.3.220, 201.3.222 and 201.3.223. These particular standard does not apply to the following: a) devices specifically intended for diagnostic or similar use (e.g. angiography or other pumps permanently controlled or supervised by the OPERATOR); b) devices for extracorporeal circulation of blood; c) implantable devices; d) ME EQUIPMENT specifically intended for diagnostic use within urodynamics (measurement of pressure-volume relationship of the urinary bladder when filled through a catheter with water); e) ME EQUIPMENT specifically intended for diagnostic use within male impotence testing (measurement of amount of liquid infused, necessary to maintain a preset pressure level for maintaining penile erection: cavernosometry, cavernosography); f) devices covered by ISO 28620. ————————— The general standard is IEC 60601-1:2005+A1:2012, Medical electrical equipment – Part 1: General require
Contents:
- FOREWORD
- INTRODUCTION
- 201.10 Protection against unwanted and excessive radiation HAZARDS
- 201.11 Protection against excessive temperatures and other HAZARDS
- 201.12 *Accuracy of controls and instruments and protection against hazardous
- 201.13 HAZARDOUS SITUATIONS and fault conditions
- 201.14 PROGRAMMABLE ELECTRICAL MEDICAL SYSTEMS (PEMS)
- 201.15 Construction of ME EQUIPMENT
- 201.16 ME SYSTEMS
- 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS