Medical electrical equipment – Part 2-62: Particular requirements for the basic safety and essential performance of high intensity therapeutic ultrasound (HITU) equipment
Introduction: In this particular standard, safety requirements additional to those in the general standard are specified for HIGH INTENSITY THERAPEUTIC ULTRASOUND (HITU) EQUIPMENT. This particular standard takes into account IEC 62555 and IEC/TS 62556. The requirements are followed by specifications for the relevant tests. A rationale for the more important requirements, where appropriate, is given in Annex AA. It is considered that knowledge of the reasons for these requirements will not only facilitate the proper application of the particular standard but will, in due course, expedite any revision necessitated by changes in clinical practice or as a result of developments in technology. However this annex does not form part of the requirements of this standard.
Scope: Addition: This International Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of HIGH INTENSITY THERAPEUTIC ULTRASOUND EQUIPMENT as defined in 201.3.218, hereafter referred to as ME EQUIPMENT. This International Standard adds or replaces clauses listed in the IEC 60601-1 that are specific for HIGH INTENSITY THERAPEUTIC ULTRASOUND EQUIPMENT. If a clause or subclause is specifically intended to be applicable to ME EQUIPMENT only, or to ME SYSTEMS only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to ME EQUIPMENT and to ME SYSTEMS, as relevant. HAZARDS inherent in the intended physiological function of ME EQUIPMENT or ME SYSTEMS within the scope of this standard are not covered by specific requirements in this standard except in 7.2.13 and 8.4.1 of the general standard. NOTE 1 See also 4.2 of the general standard. NOTE 2 As, in HITU fields, the acoustic waveform is expected to be extremely distorted due to non-linear propagation effects, the ultrasonic measurements are to be made under quasi linear conditions and then extrapolated following procedures given in IEC/TS 62556. See also IEC/TS 61949 This standard can also be applied to: therapeutic equipment for thrombolysis through exposure to high-intensity therapeutic ultrasound; therapeutic equipment for the treatment of occluding feeding vessels through exposure to high-intensity focused ultrasound; equipment intended to be used for relieving cancer pain due to bone metastases. This particular standard does not apply to: • ULTRASOUND EQUIPMENT intended to be used for physiotherapy (use: IEC 60601-2-5 [1]2) and IEC 61689); • ULTRASOUND EQUIPMENT intended to be used for lithotripsy (use: IEC 60601-2-36 [2]); • ULTRASOUND EQUIPMENT intended to be used for dedicated hyperthermia devices; • ULTRASOUND EQUIPMENT intended to be used for phacoemulsification. ————————— 1) The general standard is IEC 60601-1:2005, Medical electrical equipment – Part 1: General requirements for basic safety and essential performance 2) Numbers in square brackets refer to the Bibibliography. – 8 – 60601-2-62 © IEC:2013 201.1.2 Object Replacement: The
Contents: