IEC 60601-2-68-2025 PDF

IEC 60601-2-68-2025 PDF

Medical electrical equipment-Part 2-68: Particular requirements for the basic safety and essential performance of X-ray-based image-guided radiotherapy equipment for use with electron accelerators, light ion beam therapy equipment and radionuclide beam therapy equipment

$239.59 $479.18 -50%
Product Code: IEC 60601-2-68
Stock In Stock
Edition: 2.0
Published: 02/2025
Number of Pages: 130
File Size: 1 file, 1 Byte

Available Options

Product Description

Medical electrical equipment – Part 2-68: Particular requirements for the basic safety and essential performance of X-ray-based image-guided radiotherapy equipment for use with electron accelerators, light ion beam therapy equipment and radionuclide beam therapy equipment

Introduction: Modern RADIOTHERAPY practices utilize information from various imaging modalities, acquired prior to initiating administration of the therapy, to plan the TREATMENT. The imaging provides information about the location of the TARGET VOLUME and other anatomical features so that a TREATMENT PLAN can be developed that provides an optimal dose distribution to have the best chance of achieving the intended effect of TREATMENT while minimizing side effects. However, difficulties arise when trying to administer the RADIATION, since TARGET VOLUMES/critical structures are constantly moving within the body. For example, in parts of the body moving with respiration, the TARGET VOLUMES/critical structures may change position or shape during the RADIATION BEAM delivery throughout any given fraction. Furthermore, a course of therapy can extend over many days, during which the TARGET VOLUME/PATIENT can shrink or grow or move. Hence, the exact location of the TARGET VOLUME/critical structures can change between the time of TREATMENT PLANNING imaging and the actual administration of a TREATMENT. IMAGE-GUIDED RADIOTHERAPY (IGRT) combines planar or volumetric imaging during the course of RADIOTHERAPY to adjust the TREATMENT delivery based on the PATIENT anatomy and PATIENT position. This enables the OPERATOR or EXTERNAL BEAM EQUIPMENT (EBE) to adjust the RADIATION BEAM delivery based on the imaging information, such as the position of the TARGET VOLUME, critical organs or other reference feature

Contents:

  • FOREWORD
  • INTRODUCTION
  • 201.1 Scope, object and related standards
  • 201.2 Normative references
  • 201.3 Terms and definitions
  • 201.4 General requirements
  • 201.5 General requirements for testing ME EQUIPMENT
  • 201.6 Classification of ME EQUIPMENT and ME SYSTEMS
  • 201.7 ME EQUIPMENT identification, marking and documents
  • 201.8 Protection against electrical HAZARDS from ME EQUIPMENT
  • 201.9 Protection against MECHANICAL HAZARDS of ME EQUIPMENT and ME SYSTEMS
  • 201.10 Protection against unwanted and excessive radiation HAZARDS
  • 201.11 Protection against excessive temperatures and other HAZARDS
  • 201.12 Accuracy of controls and instruments and protection against hazardous outputs
  • 201.13 Hazardous situations and fault conditions for ME EQUIPMENT
  • 201.14 PROGRAMMABLE ELECTRICAL MEDICAL SYSTEMS (PEMS)
  • 201.15 Construction of ME EQUIPMENT
  • 201.16 ME SYSTEMS
  • 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS
  • 203 RADIATION protection in diagnostic X-RAY EQUIPMENT
  • 206 Usability

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
IEC 60601-2-68-2025 PDF

IEC 60601-2-68-2025 PDF

$239.59 $479.18