IEC 60627-2013 PDF

IEC 60627-2013 PDF

Diagnostic X-ray imaging equipment-Characteristics of general purpose and mammographic anti-scatter grids

$163.93 $327.86 -50%
Product Code: IEC 60627
Stock In Stock
Edition: 3.0
Published: 07/2013
Number of Pages: 74
File Size: 1 file, 612 Bytes

Available Options

Product Description

Diagnostic X-ray imaging equipment – Characteristics of general purpose and mammographic anti-scatter grids

Introduction: The first edition of IEC 60627 was intended for ANTI-SCATTER GRIDS used in general radiography and is not appropriate for ANTI-SCATTER GRIDS used in mammography. As a consequence, a complementary standard IEC 61953 was published. Later, it was decided to revise and merge together the two standards covering ANTI-SCATTER GRIDS. Wherever possible, a harmonized approach has been used. This constituted the second edition of IEC 60627 published in 2001. This third edition is a revision of the second edition. This revision was initiated by the fact that calcium tungstate phosphors have become obsolete, and are no longer available. Instrumentation with FLUORESCENT SCREENS made of gadolinium oxysulphide (GOS) is the present state of the art. Further, a new quality parameter is introduced: the IMAGE IMPROVEMENT FACTOR Q. This factor better describes the properties of ANTI-SCATTER GRIDS than the GRID EXPOSURE FACTOR B and the CONTRAST IMPROVEMENT FACTOR K, especially for digital detector applications. Namely, the signal-to-noise ratio (SNR) for digital X-ray detectors is increased proportionally with the square root of the factor Q when an ANTI-SCATTER GRID is applied. This effect is due to the efficient reduction of SCATTERED RADIATION and overcompensates the loss of PRIMARY RADIATION when using an ANTI-SCATTER GRID in situations where a considerable amount of SCATTERED RADIATION is present. The name IMAGE IMPROVEMENT FACTOR is chosen to reflect the improved image quality (characterize

Scope: This International Standard is applicable to ANTI-SCATTER GRIDS used in medical diagnostic X- ray imaging equipment. ANTI-SCATTER GRIDS are used to reduce the incidence of SCATTERED RADIATION, produced particularly in the body of the PATIENT, upon the IMAGE RECEPTION AREA and thus to improve the contrast of the X-RAY PATTERN. This International Standard specifies the definitions, determination and indication of characteristics of ANTI-SCATTER GRIDS. In this standard only LINEAR GRIDS are considered. Since at present only FOCUSED GRIDS are used in mammography, this standard is restricted to FOCUSED GRIDS where MAMMOGRAPHIC ANTI-SCATTER GRIDS are concerned. This standard is not intended to be applied for ACCEPTANCE TESTS. This standard does not cover the homogeneity of performance over the area of a grid. This standard is intended to be applied for the determination of the characteristics of ANTI- SCATTER GRIDS under test conditions. These conditions are not usually available at the site of the RESPONSIBLE ORGANIZATION.

Contents:

  • FOREWORD
  • INTRODUCTION
  • Scope

Be the first to write a review for this product.