Switches for household and similar fixed electrical installations-Part 2-2: Particular requirements-Electromagnetic remote-control switches (RCS) (Extended Version)

$460.90 $921.79 -50%
Product Code: IEC 60669-2-2 EXV
Stock In Stock
Edition: 4.0
Published: 03/2024
Number of Pages: 180
File Size: 1 file

Available Options

Product Description

Switches for household and similar fixed electrical installations – Part 2-2: Particular requirements – Electromagnetic remote-control switches (RCS) (Extended Version)

Scope: This part of IEC 60669 applies to electromagnetic remote control switches (hereinafter referred to as electromagnetic RCS) with a rated voltage not exceeding 440 V AC and a rated current not exceeding 63 A, intended for household and similar fixed electrical installations, either indoors or outdoors. For the control circuit, the rated control voltage does not exceed 440 V AC or 220 V DC. The RCS coil can be either permanently energized or not permanently energized. Electronic RCS are within the scope of IEC 60669-2-1 but not of this document. RCS including only passive components such as resistors, capacitors, positive temperature coefficient (PTC) and negative temperature coefficient (NTC) components and printed circuit boards are not considered to be electronic RCS. Electromechanical contactors for household and similar purposes are within the scope of IEC 61095. For switches provided with screwless terminals, the rated current is limited to 16 A. NOTE 1 The rated current is limited to 16 A for switches provided with insulation piercing terminals (IPT’s) according to Annex D. Switches covered by this document are, where applicable, intended for the control in normal use of all of the following loads: a circuit for a tungsten filament lamp load; a circuit for an externally ballasted lamp load (for example LED, CFL, fluorescent lamp load); a circuit for a self ballasted lamp load (for example LEDi or CFLi); a circuit for a substantially resistive load with a power factor not less than 0,95; a single phase circuit for motor load with a rated current not exceeding 3 A at 250 V (750 VA) and 4,5 A at 120 V (540 VA) and a power factor not less than 0,6. This applies to both switches rated not less than 10 A that have not undergone additional tests and to momentary switches rated not less than 6 A that have not undergone additional tests. NOTE 2 In the following country the suitability of a switch intended to control the inrush current of a motor shall be tested: AU. This document also applies to boxes for switches, with the exception of mounting boxes for flush-type switches. NOTE 3 General requirements for boxes for flush-type switches are given in IEC 60670-1. It a

Contents:

  • FOREWORD
  • Scope
  • 5.101 Incorporated hand-operated device
  • 6.101 Rated control voltage