Switches for household and similar fixed electrical installations-Part 2-3: Particular requirements-Time-delay switches (TDS)

$460.90 $921.79 -50%
Product Code: IEC 60669-2-3 EXV
Stock In Stock
Edition: 4.0
Published: 03/2024
Number of Pages: 178
File Size: 1 file, 2.4 MB

Available Options

Product Description

Switches for household and similar fixed electrical installations – Part 2-3: Particular requirements – Time-delay switches (TDS)

Scope: This part of IEC 60669 applies to time-delay switches (hereinafter referred to as TDS) with a rated voltage not exceeding 440 V AC and a rated current not exceeding 63 A, intended for household and similar fixed electrical installations, either indoors or outdoors, operated by hand and/or by remote control. For the control circuit, the rated control voltage does not exceed 440 V AC or 220 V DC. TDS are provided with a time-delay device operated by mechanical, thermal, pneumatic, hydraulic or electrical means or by a combination of them. Electronic TDS are within the scope of IEC 60669-2-1 but not of this document. TDS including only passive components such as resistors, capacitors, positive temperature coefficient (PTC) and negative temperature coefficient (NTC) components and printed circuit boards are not considered to be electronic TDS. For switches provided with screwless terminals, the rated current is limited to 16 A. NOTE 1 The rated current is limited to 16 A for switches provided with insulation piercing terminals (IPT’s) according to Annex D. Switches covered by this document are, where applicable, intended for the control in normal use of all of the following loads: a circuit for a tungsten filament lamp load; a circuit for an externally ballasted lamp load (for example LED, CFL, fluorescent lamp load); a circuit for a self ballasted lamp load (for example LEDi or CFLi); a circuit for a substantially resistive load with a power factor not less than 0,95; a single phase circuit for motor load with a rated current not exceeding 3 A at 250 V (750 VA) and 4,5 A at 120 V (540 VA) and a power factor not less than 0,6. This applies to both switches rated not less than 10 A that have not undergone additional tests and to momentary switches rated not less than 6 A that have not undergone additional tests. NOTE 2 In the following country the suitability of a switch intended to control the inrush current of a motor shall be tested: AU. This document also applies to boxes for switches, with the exception of mounting boxes for flush-type switches. NOTE 3 General requirements for boxes for flush-type switches are given in IEC 60670-1. It also applies to switches su

Contents:

  • FOREWORD
  • Scope
  • 5.101 Incorporated hand-operated device
  • 5.102 Operated by hand
  • 5.103 Control and switching circuits without common point
  • 6.101 Rated control voltage