IEC 60724-2008 PDF

IEC 60724-2008 PDF

Short-circuit temperature limits of electric cables with rated voltages of 1 kV (Um = 1,2 kV) and 3 kV (Um = 3,6 kV)

$53.59 $107.18 -50%
Product Code: IEC 60724
Stock In Stock
Edition: 3.1
Published: 11/2008
Number of Pages: 24
File Size: 1 file, 881 Bytes

Available Options

Product Description

Short-circuit temperature limits of electric cables with rated voltages of 1 kV (Um = 1,2 kV) and 3 kV (Um = 3,6 kV)

Introduction: Editorially, this third edition of IEC 60724 is brought into line with IEC 60986, second edition, and IEC 61443, first edition. The following four aspects may be applicable when selecting the short-circuit rating of a cable system: a) the permissible maximum temperature limits for cable components (e.g. conductor, insulation, screen or metallic sheath, bedding, armour and oversheath). For practical purposes, the energy producing the temperature rise is usually expressed by an equivalent (I2t) value so that the permitted maximum duration for a given short-circuit current can be calculated; b) the maximum value of current which will not cause mechanical failure (such as bursting) due to electromagnetic forces. Irrespective of any temperature limitations, this determines a maximum current which should not be exceeded; c) the thermal performance of joints and terminations at the limits of current and duration specified for the associated cable. Accessories should also withstand the thermo- mechanical and electromagnetic forces produced by the short-circuit current in the cable; d) the influence of installation conditions on the above three aspects. Aspect a) is dealt with in detail, and the limits given are based on a consideration of the cable only. A single short-circuit application is not expected to produce any significant damage to the cable, but repeated short-circuits may cause cumulative damage. Guidance is given, where appropriate, on aspects c) and d) mainly as they con

Scope: This International Standard gives guidance on the short-circuit maximum temperature limits of electric cables having rated voltages of 1 kV (Um = 1,2 kV) and 3 kV (Um = 3,6 kV), with regard to the following: insulating materials; oversheath and bedding materials; conductor and metallic sheath materials and methods of connection. The design of accessories and the influence of the installation conditions on the temperature limits are taken into consideration. The calculation of the permissible short-circuit current in the current-carrying components of the cable should be carried out in accordance with IEC 60949.

Contents:

  • FOREWORD
  • INTRODUCTION
  • Scope