Standard Test Procedures for Semiconductor X-Ray Energy Spectrometers

Scope: This standard presents standard test procedures for semiconductor X-ray energy spectrometers. Such systems consist of a semiconductor radiation detector assembly and signal processing electronics interfaced to pulse-height analyzer/computer. Test procedures for pulse-height analyzers and computers are not covered in this standard. Clause 5 is essentially tutorial. 2. Object This standard is not intended to imply that all tests described herein are mandatory, but only that such tests· as are carried out shall be performed in accordance with the procedures described herein. Companion pubHcations to this standard are IE C Publication 333: Test Procedures for Semiconductor Detectors for Ionizing Radiation, IE C Publication 340: Test Procedures for Amplifiers and Preamplifiers for Semiconductor Detectors for Ionizing Radiation, and IEC Publication 656: Test Procedures for High-purity Germanium Detectors for X and Gamma Radiation. The list of symbols and the glossary are derived from those in the above-mentioned publications. Contrary to previous convention in the X-ray spectroscopy field, this standard utilizes the characteristic energy E of the X-ray rather than its wavelength A-. This approach is consistent with the fact that the basic quantity measured by this type of spectrometer is the X-ray energy. A convenient conversion is provided by the relationship: Jc (m) = 12.4 · 10-10 E-1 (keV) (Jc (A) = 12.4 · E-1 (ke V)) 3. Glossary (according to English alphabetical order) Analog to digital converter (ADC) A sub-assembly designed to provide an output signal which is a digital representation of the analog input signal (IEV 391-11-36). Background (associated with a spectral peak from a semiconductor detector) Non-ideal spectral response which results from radiation which is not a part of the monoenergetic line of interest. Baseline (at pulse peak) The instantaneous value that the voltage would have had at the time of the pulse peak in the absence of that pulse (IE C Publication 340).

Contents:

  • FOREWORD
  • 6.2 General precautions and specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
  • 7.4 X-ray linewidth measurements by pulse-height distribution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
  • 9.4 Counting losses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
  • 10.2 Amplifier gain recovery time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
  • 11.2 Temperature effects . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
  • 12.2 Window attenuation measurement with radioactive sources . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .