Telecontrol equipment and systems – Part 6-503: Telecontrol protocols compatible with ISO standards and ITU-T recommendations – TASE.2 Services and protocol
Introduction: The Telecontrol Application Service Element (TASE.2) protocol (also known as Inter-Control Centre Communications Protocol, ICCP) allows for data exchange over Wide Area Networks (WANs) between a utility control centre and other control centres, other utilities, power pools, regional control centres, and Non-Utility Generators. Data exchange information consists of real-time and historical power system monitoring and control data, including measured values, scheduling data, energy accounting data, and operator messages. This data exchange occurs between one control centre's Supervisory Control And Data Acquisition/Energy Management System/Distribution Management System (SCADA/EMS/DMS) host and another centre's host, often through one or more intervening communications processors. This part of IEC 60870 defines a mechanism for exchanging time-critical data between control centres. In addition, it provides support for device control, general messaging and control of programs at a remote control centre. It defines a standardized method of using the ISO 9506 Manufacturing Message Specification (MMS) services to implement the exchange of data. The definition of TASE.2 consists of three documents. This part of IEC 60870 defines the TASE.2 application modelling and service definitions. IEC 60870-6-702 defines the application profile for use with TASE.2. IEC 60870-6-802 defines a set of standardized object definitions to be supported. The TASE.2 describes real control centres with res
Scope: 1.1 General This part of IEC 60870 specifies a method of exchanging time-critical control centre data through wide-area and local-area networks using a full ISO compliant protocol stack. It contains provisions for supporting both centralized and distributed architectures. This standard includes the exchange of real-time data indications, control operations, time-series data, scheduling and accounting information, remote program control and event notification. Though the primary objective of TASE.2 is to provide control centre (telecontrol) data exchange, its use is not restricted to control centre data exchange. It may be applied in any other domain having comparable requirements. Examples of such domains are power plants, factory automation, process control automation, and others. This standard does not specify individual implementations or products, nor does it constrain the implementation of entities and interfaces within a computer system. This standard specifies the externally visible functionality of implementations together with conformance requirements for such functionalities. 1.2 Control centre The model of a control centre includes four primary classes of host processors: SCADA/EMS, Demand Side Management (DSM)/ Load Management, Distributed Applications, and Display Processors. The SCADA/EMS host is the primary processor, utilizing analogue and digital monitoring data collected at power plants, Non-Utility Generators, and transmission and distribution substations via Data Acquisition Units (DAUs) and Remote Terminal Units (RTUs). The control centre typically contains redundant SCADA/EMS/DMS hosts in a "hot standby" configuration. The DSM/Load Management host(s) are used by either an operator or EMS application to initiate load management activities. The Distributed Application host(s) perform miscellaneous analysis, scheduling, or forecasting functions. Display Processors allow for local operator and dispatcher display and control. Typically, the control centre will contain one or more Local Area Networks (LANs) to connect these various hosts. The control centre will also access several WANs, often through intermediate communications processors. These
Contents:
- FOREWORD
- INTRODUCTION
- Scope