Nuclear power plants – Instrumentation systems – Measurements for monitoring adequate cooling within the core of pressurized light water reactors

Introduction: a) Technical background, main issues and organisation of the document This document focuses on the methods and requirements relating to the measurement of adequate cooling within the core of pressurised water reactors. Adequate core cooling can be achieved only by providing sufficient coolant flow to the core to remove the heat. Under normal power operation, cooling of the core is adequately monitored by the normal reactor protection measurement. Normally, the coolant is forced circulation to facilitate the heat transfer. However, during certain abnormal shutdown conditions, the coolant might circulate naturally, or the coolant might even become stationary. The coolant can be in one phase or two phases: 1) one phase: either liquid, or steam, or a mixture of steam and gas; 2) two phases: a mixture of liquid and steam or gas. To monitor that adequate cooling is being achieved under those abnormal conditions for which operator action can be necessary or for which confirmation of coolant inventory status is of value, sufficient measurements of the coolant inventory shall be provided, including the level measurement. Measurement of the subcooling and its time history shall also be provided to assist the operator in avoiding those abnormal conditions. It is intended that this document be used by operators of NPPs (utilities), systems evaluators and by licensors. b) Situation of the current document in the structure of the IEC SC45A standard series IEC 60911 is a level 3 IEC SC 45A

Scope: This document applies to pressurized water reactors (PWRs) and presents requirements for the monitoring of adequate cooling within the core in all operations, including normal and abnormal operations. Requirements for core cooling monitoring during conditions beyond a design basis accident, i.e. a design extension condition of type A or type B, are also covered in this document. This document defines requirements for instrumentation to measure coolant parameters, which are of interest when abnormal conditions arise with either one or two phases of coolant or with gas included in the reactor pressure vessel (RPV). PWR users can acquire this instrumentation to present information on coolant conditions, to assist the operator to decide on actions necessary to maintain adequate core cooling. Typical applications in operating nuclear power plants are also presented in this document.

Contents:

  • FOREWORD
  • INTRODUCTION
  • Scope