AC and/or DC-supplied electronic control gear for tubular fluorescent lamps – Performance requirements
Introduction: This International Standard covers performance requirements for electronic control gear for use on a.c., at 50 Hz or 60 Hz, and/or d.c. supplies up to 1 000 V with operating frequencies deviating from the supply frequency, associated with tubular fluorescent lamps as specified in IEC 60081 and IEC 60901, and other tubular fluorescent lamps for high frequency operation, still to be standardised. These control gear are intended to operate lamps at various frequencies including high frequencies and at various lamp powers. Attention is drawn to the fact that operating frequencies below 20 kHz may cause audio noise disturbance, whereas frequencies above 50 kHz may increase radio interference problems. Some lamps may be specifically designed for high-frequency operation on high-frequency control gear. Two starting modes, preheat and non-preheat, are described. NOTE Lamps, only specified for preheat starting may be operated on other types of circuits. The control gear manufacturer should provide test data which shows satisfactory starting and operation similar as the ones stated in Clause 6. In order to obtain satisfactory performance of fluorescent lamps and electronic control gears, it is necessary that certain features of their design be properly co-ordinated. It is essential, therefore, that specifications for them be written in terms of measurement made against some common baseline of reference, permanent and reproducible. These conditions may be fulfilled by reference ballasts
Scope: This international Standard specifies performance requirements for electronic control gear for use on a.c. at 50 Hz or 60 Hz and/or d.c. supplies, both up to 1 000 V, with operating frequencies deviating from the supply frequency, associated with fluorescent lamps as specified in IEC 60081 and IEC 60901, and other fluorescent lamps for high-frequency operation. NOTE 1 Tests in this standard are type tests. Requirements for testing individual control gear during production are not included. NOTE 2 There are regional standards regarding the regulation of mains current harmonics and immunity for end- products like luminaires and independent control gear. In a luminaire, the control gear is dominant in this respect. Control gear, together with other components, should comply with these standards. NOTE 3 Requirements for the digital addressable lighting interface of electronic control gear are given in IEC 62386.
Contents:
- FOREWORD
- INTRODUCTION
- Scope
- 10 Supply current
- 11 Maximum current in any lead to a cathode
- 12 Lamp operating current waveform
- 13 Impedance at audio frequencies
- 14 Operational tests for abnormal conditions
- 14.1 Removal of lamp(s)
- 14.2 Lamp fails to start
- 14.3 Control gear behaviour close to end of lamp life
- 15 Endurance
- 15.1 General
- 15.2 Temperature cycling
- 15.3 Test at tc +10 K