Electroacoustics – Sound calibrators
Introduction: Sound calibrators are designed to produce one or more known sound pressure levels at one or more specified frequencies when coupled to specified models of microphone in specified configurations, for example, with or without protective grid. The sound pressure level generated by a some sound calibrators may depends on environmental conditions such as the static pressure, air temperature and relative humidity. Sound calibrators have two principal applications: a) the determination of the electroacoustical pressure sensitivity of specified models of microphone in specified configurations; b) checking or adjusting the overall sensitivity of acoustical measuring devices or systems.
Scope: This document specifies the performance requirements for three classes of sound calibrator: class LS (Laboratory Standard), class 1 and class 2. Tolerance Acceptance limits are smallest for class LS and greatest for class 2 instruments. Class LS sound calibrators are normally used only in the laboratory; class 1 and class 2 are considered as sound calibrators for field use. A class 1 sound calibrator is primarily intended for use with a class 1 sound level meter and a class 2 sound calibrator primarily with a class 2 sound level meter, as specified in IEC 61672-1. The tolerance acceptance limits for class LS sound calibrators are based on the use of a laboratory standard microphone, as specified in IEC 61094-1, for demonstrations of conformance to the requirements of this document. The tolerance acceptance limits for class 1 and class 2 sound calibrators are based on the use of a working standard microphone, as specified in IEC 61094-4, for demonstrations of conformance to the requirements of this document. A multi-level and multi-frequency sound calibrator has the same class designation for all sound pressure level and frequency combinations for which the instruction manual states that the instrument conforms to the requirements of this standard. To promote consistency of testing of sound calibrators and ease of use, this document contains three normative annexes – Annex A "Pattern evaluation tests", Annex B "Periodic tests", Annex C "Pattern evaluation report", and two informative Annexes – Annex D "Relationship between tolerance interval, corresponding acceptance interval and the maximum-permitted uncertainty of measurement" and Annex E "Example assessments of conformance to specifications of this document". This document does not include requirements for equivalent free-field or random-incidence sound pressure levels, such as may can be used in the overall sensitivity adjustment of a sound level meter. A sound calibrator may can provide other functions, for example, tonebursts. Requirements for these other functions are not included in this document.
Contents:
- FOREWORD
- INTRODUCTION
- Scope