Information technology equipment – Safety – Part 1: General requirements
Introduction: Principles of safety The following principles have been adopted by technical committee 108 in the development of this standard. These principles do not cover performance or functional characteristics of equipment. Words printed in SMALL CAPITALS are terms that are defined in 1.2 of this standard. 0.1 General principles of safety It is essential that designers understand the underlying principles of safety requirements in order that they can engineer safe equipment. These principles are not an alternative to the detailed requirements of this standard, but are intended to provide designers with an appreciation of the basis of these requirements. Where the equipment involves technologies, components and materials or methods of construction not specifically covered, the design of the equipment should provide a level of safety not less than those described in these principles of safety. NOTE The need for additional detailed requirements to cope with a new situation should be brought promptly to the attention of the appropriate committee. Designers shall take into account not only normal operating conditions of the equipment but also likely fault conditions, consequential faults, foreseeable misuse and external influences such as temperature, altitude, pollution, moisture, overvoltages on the MAINS SUPPLY and overvoltages on a TELECOMMUNICATION NETWORK or a CABLE DISTRIBUTION SYSTEM. Dimensioning of insulation spacings should take account of possible reductions by manufacturing tol
Scope: 1.1.1 Equipment covered by this standard This standard is applicable to mains-powered or battery-powered information technology equipment, including electrical business equipment and associated equipment, with a RATED VOLTAGE not exceeding 600 V. This standard is also applicable to such information technology equipment: designed for use as telecommunication terminal equipment and TELECOMMUNICATION NETWORK infrastructure equipment, regardless of the source of power; designed and intended to be connected directly to, or used as infrastructure equipment in, a CABLE DISTRIBUTION SYSTEM, regardless of the source of power; designed to use the AC MAINS SUPPLY as a communication transmission medium (see Clause 6, Note 4 and 7.1, Note 4). This part of IEC 60950 is also applicable to: components and subassemblies intended for incorporation in information technology this equipment. It is not expected that Such components and subassemblies need not comply with every aspect requirement of the standard, provided that the complete information technology equipment, incorporating such components and subassemblies, does comply; external power supply units intended to supply other equipment within the scope of this part of IEC 60950; accessories intended to be used with equipment within the scope of this part of IEC 60950. NOTE 1 Examples of aspects with which uninstalled components, subassemblies and accessories may not comply include the marking of the power rating and access to hazardous parts. NOTE 2 This standard may be applied to the electronic parts of equipment even if that equipment does not wholly fall within its Scope, such as large-scale air conditioning systems, fire detection systems and fire extinguishing systems. Different requirements may be necessary for some applications. This standard specifies requirements intended to reduce risks of fire, electric shock or injury for the OPERATOR and layman who may come into contact with the equipment and, where specifically stated, for a SERVICE PERSON. This standard is intended to reduce such risks with respect to installed equipment, whether it consists of a system of interconnected units or independent units, subject to i
Contents:
- FOREWORD
- INTRODUCTION
- Scope
- 2.10 Clearances, creepage distances and distances through insulation