Nuclear facilities – Instrumentation systems important to safety – Radiation monitoring for accident and post-accident conditions – Part 3: Equipment for continuous high range area gamma monitoring
Introduction: a) Technical background, main issues and organisation of the standard This IEC standard specifically focuses on radiation monitoring systems (RMSs) used for accident and post-accident operations. According to the lessons learned from the Fukushima-Daiichi accident, it re-acknowledges a need to provide operators with reliable radiation monitoring data to allow them to understand the plant state during and after the accident conditions. To support the design of such instrumentation, it is necessary to provide general guidance on the design principles and performance criteria for radiation monitoring instrumentation applied during and after the accident conditions. In addition, the scope of IEC 63147 which provides criteria for accident monitoring instrumentation for nuclear power generating stations has evolved to include severe accident (SA) to accident conditions. Thus to address the specific lessons learned from the Fukushima-Daiichi accident, this standard categorizes accident condition into design basis accidents (DBA) and design extension conditions (DEC) including severe accident (SA). This standard is intended for use by purchasers in developing specifications for their plant- specific radiation monitoring systems and by manufacturers to identify needed product equipment characteristics when developing systems for accident monitoring conditions. Some specific instrument characteristics such as measurement range, required energy response, and ambient environment requirem
Scope: Sampling circuits and methods Accident and post- accident conditions Normal and incident conditions Gas, particulate and iodine with sampling (OFF LINE) ISO 2889 IEC 60951-1 and IEC 60951-2 IEC 60761 series and IEC 62302 (noble gases only) Liquid with sampling (OFF LINE) N/A N/A IEC 60861 Process streams (gaseous effluents, steam or liquid) without sampling (ON or IN-LINE) N/A IEC 60951-1 and IEC 60951-4 IEC 60768 N/A Area monitoring N/A IEC 60951-1 and IEC 60951-3 IEC 60532 Central system N/A IEC 61504 IEC 61559 Developer ISO IEC SC45A SC45B Scope Sampling (Normal operation) Calibration (Normal operation) Normal operation, AOO DBA DEC Normal operation Radioactive noble gas off-line monitoring ISO 2889 ISO 4037-1, ISO 4037-3 N/A IEC 60951-1, IEC 60951-2 N/A IEC 62302, IEC 60761- 1, IEC 60761-3 Radioactive aerosol off-line monitoring ISO 2889 ISO 4037-1, ISO 4037-3 N/A IEC 60951-1, IEC 60951-2 N/A IEC 60761- 1, IEC 60761-2 Radioactive iodine off-line monitoring ISO 2889 ISO 4037-1, ISO 4037-3 N/A IEC 60951-1, IEC 60951-2 N/A IEC 60761- 1, IEC 60761-4 Liquid off-line monitoring N/A N/A N/A N/A N/A IEC 60861 Tritium off-line monitoring N/A N/A N/A N/A N/A IEC 62303, IEC 60761- 1, IEC 60761-5 On-line or in-line monitoring N/A ISO 4037-1, ISO 4037-3 IEC 60768 IEC 60951-1, IEC 60951-4 N/A N/A Area monitoring N/A ISO 4037-1, ISO 4037-3 IEC 61031 IEC 60951-1, IEC 60951-3 IEC 60532 Centralized system N/A N/A IEC 61504, IEC 60960 N/A IEC 61559-1 Classification/basic requirements N/A N/A IEC 61513, IEC 60880, IEC 60987, IEC 61226, IEC 62138, IEC 62566, IEC 62566-2, IEC 62645, IEC 61250 N/A N/A Qualification N/A N/A IEC/IEEE 60780-323, IEC/IEEE 60980-344, IEC 62003 N/A IEC 62706 – 8 – IEC 60951-3:2022 RLV © IEC 2022 For more details on the structure of the IEC SC 45A standard series, see the item d) of this introduction. c) Recommendations and limitations regarding the application of this standard It is important to note that this standard establishes no additional functional requirements for safety systems important to safety. d) Description of the structure of the IEC SC 45A standard series and relationships with other IEC documents and other bodies documents (IAEA, ISO)
Contents:
- FOREWORD
- INTRODUCTION
- Scope