Insulating liquids – Methods for counting and sizing particles

Introduction: The first edition of this standard was published in 1989, and confirmed in 1996. The present edition has been found necessary for consistency with the new ISO 4406:1999, in which calibration procedures for automated particles counters have been changed from ACFTD standard to ISO-MTD standard. Specific procedures for sample preparation are described in more detail when automated particle counters are used. Results and ISO Code reporting are consistent with ISO 4406:1999 standard. Repeatability and reproducibility data are reported. It has been demonstrated that particle contamination of insulating liquids used in electrical equipment have been responsible for major faults [1]1. Particle analysis is recommended (as complementary test) by IEC 60422[3] for power transformers with nominal voltage above 170 kV[2]. Particle counting and sizing is usually carried out using automated counters; the calibration standard for these counters was changed in 1999. The ISO reporting code has also been changed from a two-figure to a three-figure code. This code gives information on three classes of cumulative counting: particles/ml with ∅ > 4 μm, particles/ml with ∅ > 6 μm, particles/ml with ∅ > 14 μm. Particle analysis with automated particle counters has been thoroughly investigated to verify factors influencing the results and to optimize the analysis procedure. Reference figures for repeatability and Reproducibility are reported, for particle counting and for ISO Class. Annex A provides in

Scope: This standard describes the sampling procedures and methods for the determination of particle concentration and size distribution. Three methods are specified. One uses an automatic particle size analyser, working on the light interruption principle. The other two use an optical microscope, in either the transmitted light or incident light mode, to count particles collected on the surface of a membrane filter. The optical microscope methods are described in ISO 4407. All three methods are applicable to both used and unused insulating liquids. Annex A contains an alternative sampling procedure using a syringe and Annex B reports a reference for the calibration of automatic particle counters. NOTE 1 The methods are not intended to measure particulate matter in liquids containing sludge. While analysing solid content on oils containing sludge refers to method for sediment and sludge determination in IEC 60422, Annex C. NOTE 2 The methods specified are only applicable to measurements related to a limited range of size and number.

Contents:

  • FOREWORD
  • INTRODUCTION
  • Scope
  • 9.10 Repeatability
  • 9.11 Reproducibility
  • 10 Method B – Optical microscopy
  • 10.1 Principle
  • 10.2 Procedure by transmitted light
  • 10.3 Procedure by incident light