Electromagnetic compatibility (EMC) – Part 2-4: Environment – Compatibility levels in power distribution systems in industrial locations for low-frequency conducted disturbances
Introduction: IEC 61000 is published in separate parts according to the following structure: Part 1: General General considerations (introduction, fundamental principles) Definitions, terminology Part 2: Environment Description of the environment Classification of the environment Compatibility levels Part 3: Limits Emission limits Immunity limits (in so far as they do not fall under the responsibility of the product committees) Part 4: Testing and measurement techniques Measurement techniques Testing techniques Part 5: Installation and mitigation guidelines Installation guidelines Mitigation methods and devices Part 6: Generic standards Part 9: Miscellaneous Each part is further subdivided into several parts, published either as International Standards, technical specifications or technical reports, some of which have already been published as sections. Others will be published with the part number followed by a dash and a second number identifying the subdivision (example: IEC 61000-3-11). Detailed information on the various types of disturbances that can be expected on public power supply systems can be found in IEC 61000-2-1 and IEC 61000-2-12.
Scope: This part of IEC 61000 is related to conducted disturbances in the frequency range from 0 kHz to 9 150 kHz. It gives numerical compatibility levels in differential mode (L-L and L-N) for industrial locations and non-public power distribution systems, with a nominal voltage up to 35 kV and a nominal frequency of 50 Hz or 60 Hz. NOTE 1 Industrial locations are defined in 3.1.8. Power supply distribution systems on ships, aircraft, offshore platforms and railways are not included. The compatibility levels specified in this standard apply at the in-plant point of coupling. At the power input terminals of equipment receiving its supply from the above systems, the severity levels of the disturbances can, for the most part, be taken to be the same as the levels at the in-plant point of coupling. In some situations this is not so, particularly in the case of a long feeder dedicated to the supply of a particular load, or in the case of a disturbance generated or amplified within the installation of which the equipment forms a part. NOTE 2 See also Annex E. The compatibility levels specified in this document apply at the in-plant point of coupling (IPC). The level of the low-frequency disturbances at the terminals of equipment receiving its supply from the IPC is generally assumed to be similar to the disturbance level at the IPC itself. However, in some situations this is not the case, particularly when a long feeder is dedicated to the supply of a particular load, or when a disturbance is generated or amplified within the installation of which the equipment forms a part. Compatibility levels are specified for the types of low-frequency electromagnetic disturbances of the types which can be expected at any in-plant point of coupling (IPC) within industrial plants or other non-public networks locations, for guidance in the definition of: a) limits for disturbance emissions in industrial power supply distribution systems (including the planning levels defined in 3.1.5); NOTE 3 A very wide range of conditions is possible in the electromagnetic environments of industrial and other non-public networks. These are approximated in this document by the three classes described in
Contents:
- FOREWORD
- INTRODUCTION
- Scope