Electromagnetic compatibility (EMC) - Part 4-23: Testing and measurement techniques - Test methods for protective devices for HEMP and other radiated disturbances
Introduction: IEC 61000 is published in separate parts, according to the following structure: Part 1: General General considerations (introduction, fundamental principles) Definitions, terminology Part 2: Environment Description of the environment Classification of the environment Compatibility levels Part 3: Limits Emission limits Immunity limits (in so far as they do not fall under the responsibility of the product committees) Part 4: Testing and measurement techniques Measurement techniques Testing techniques Part 5: Installation and mitigation guidelines Installation guidelines Mitigation methods and devices Part 6: Generic Standards Part 9: Miscellaneous Each part is further subdivided into several parts, published either as international standards, as technical specifications or technical reports, some of which have already been published as sections. Others will be published with the part number followed by a dash and a second number identifying the subdivision (example: IEC 61000-6-1). The IEC has initiated the preparation of standardized methods to protect civilian society from the effects of high power electromagnetic (HPEM) environments. Such effects could disrupt systems for communications, electric power, information technology, etc. This part of IEC 61000 is an international standard that establishes the test concepts, set-ups, required equipment, and test procedures for protective devices against HEMP radiated disturbances. Annex F provides examples of the SE test method pla
Scope: This part of IEC 61000 provides a protective devices test method for HEMP and other radiated disturbances. It is primarily intended for HEMP testing but can be applied to other externally generated radiated disturbances where appropriate. It provides a brief description of the most important concepts for testing of shielding elements. For each test, the following basic information is provided: theoretical foundation of the test (the test concepts); test set-up including outside-to-in and inside-to-out measurements; required equipment; test procedures; data processing. This international standard does not provide information on requirements for specific levels for testing. This part of IEC 61000 has been updated to include a new test method. Due to the available space, a transmitting antenna position outside the barrier has mainly been suggested. However, nowadays, many EMP protection facilities in practical use do not actually have enough space available outside the electromagnetic barrier due to physical constraints such as concrete walls or soil to allow the method described in IEC 61000-4- 23:2000 (edition 1) to be applied correctly. From experience many facilities have available space for a 1 m separation or less only. Therefore, in many practical cases it is not possible to measure shielding effectiveness according to the test method of previous documents. The constructors for EMP protection facilities are also unwilling to build facilities with extra space for measurements with the transmitting antenna outside the barrier due to the great expense and inefficiency of the operational working area for new or existing buildings. This document provides additionally a method that allows the transmitting antenna to be placed inside the enclosure and the receiving antenna outside the barrier (‘inside-to-out’ method). Annex F includes test set-up and procedure examples.
Contents:
- FOREWORD
- INTRODUCTION
- Scope